Manual

To set Timer to turn on air conditioner, keeping previous
settings:
1. Turn off air conditioner.
2. Press TIMER. Timer indicator light on air conditioner will
flash. Hour indicator light on air conditioner will turn on, and
display on air conditioner will show remaining hours before air
conditioner will turn off.
3. Press the plus or minus button to change delay time (1 to
24 hours).
4. Press TIMER again or wait 10 seconds. Timer indicator light
on air conditioner will remain on. Hour indicator light on air
conditioner will turn off, and Room indicator light on air
conditioner will turn on. Display on air conditioner will show
the current room temperature.
To set Timer to turn on air conditioner, changing the
previous settings:
1. Turn on air conditioner.
2. Adjust Mode to Auto Cool, Cool, Fan Only, or Power Saver.
NOTE: For Auto Cool mode, go to Step 4.
3. For Cool, Fan Only or Power Saver mode, adjust Fan Speed
to Turbo, High or Low.
4. Adjust temperature between 64°F (18°C) and 86°F (30°C).
5. Wait 3 seconds before turning off air conditioner.
6. Press TIMER. Timer indicator light on air conditioner will
flash. Hour indicator light on air conditioner will turn on, and
display on air conditioner will show remaining hours before air
conditioner will turn on.
7=
8.
Press the plus or minus button to change delay time (1 to
24 hours).
Press TIMER again or wait 10 seconds. Timer indicator light
on air conditioner will remain on. Hour indicator light on air
conditioner will turn off, and Room indicator light on air
conditioner will turn on. Display on air conditioner will show
current room temperature.
Style 1 --Cool only air conditioner settings
Fan Control
Set the Fan control to the desired setting. When the air
conditioner is operating at Low Cool, High Cool or Turbo Cool,
the fan circulates air continuously.
Turbo Cool--for maximum cooling
High Cool--for normal cooling
Low Cool--for sleeping comfort
Fan Only--to move air continuously without cooling
NOTE: Fan runs on Turbo speed only.
Power Saver (on some models)--fan runs only when
cooling is needed.
Since the fan does not circulate the room air continuously,
less energy is used, but the room air is not circulated as
often. Use Power Saver when you are asleep or away
from home.
NOTE: Fan runs on Low speed only.
Your air conditioner will have one of these fan controls
FANCONTROL
1. Remove the clear protective film from the front panel badge
(on some models).
2. Set the Vent control. See "Vent Control (on some models)."
3. Set the Fan Control to desired setting. See "Fan Control" for
your model.
4. Turn the Thermostat control to a mid-setting. See
"Thermostat" for your model.
Vent Control (on some models)
Push the Vent control to CLOSED for maximum continuous
cooling. Pull the Vent control OPEN to allow you to draw stale or
smoky air from the room.
Open--pull to vent room air to the outside
Closed--push to circulate room air
OFF
FANCONTROL
A. Pull to open or push to close
NOTE: The Vent control will function only when the Fan Control is
operating.
15