Safety Instructions

Electrical Requirements
Continued
115 volt models with amperes
up through 12.0
.
Receptacle wiring
Receptacle wiring should be a minimum of
14 gauge. Use copper wire only. It is the
responsibility of the consumer to provide
proper and adequate receptacle wiring,
installed by a qualified electrician. Observe
National Electrical Code and all local governing
codes and ordinances.
Electrical requirements
A 115 volt (103.5 min., 126.5 max.), 60 Hz,
AC only, 15 ampere fused electrical supply is
required (time delay fuse or time delay circuit
breaker required). It is required that a separate
circuit, serving only this appliance, be provided.
3-prong
grounding
type wall
receptacle
Electrical connection
Electrical ground is required on this appliance.
Recommended grounding method
For your personal safety, this appliance must be
grounded. This air conditioner is equipped with a
power supply cord having a 3-prong grounding
plug. To minimize possible shock hazard, the
cord must be plugged into a mating 3-prong
grounding-type wall receptacle, grounded in
accordance with the National Electrical Code
(ANSVNFPA 70-latest edition) and local codes
and ordinances. If a mating wall receptacle is not
available, it is the responsibility of the customer to
have a properly grounded 3prong wall receptacle
installed by a qualified electrician.