Instruction for Use

23
The appliances gas inlet tting is a threaded
1/2” male cylindrical type, in compliance
with the UNI-ISO 228-1 standards. If gas is
distributed through ducts the appliance must
be connected to the gas mains with:
a rigid steel pipe, in accordance with standards,
whose joints must be made using threaded
ttings in accordance with the UNI-ISO 7/1
standard. The use of hemp with suitable
adhesives or Teon tape as a sealant is allowed.
copper pipe, in accordance with the standard,
whose joints must be made using sealed
ttings in accordance with the standard.
a exible stainless steel, seamless pipe in
accordance with the standard, with a maximum
2 metre extension and seals in accordance with
the standard.
a exible rubber hose in accordance with the
standard, with an 8 mm diameter for LPG and
13 mm for natural gas or town gas, maximum
1500 mm in length, rmly secured to the hose
tting with a safety clamp as per the standard.
If the gas is supplied directly from a gas
cylinder, the appliance, fed by a pressure
regulator in accordance with the standard, must
be connected:
with a copper pipe in accordance with
the standard, whose joints must be made
using sealed ttings in accordance with the
standard.
with a exible stainless steel, seamless
pipe in accordance with the standard,
with a maximum 2 metre extension and
seals in accordance with the standard. We
recommend applying the special adapter to
INSTRUCTIONS FOR THE INSTALLER
the exible pipe, easily found on the market,
to facilitate connection to the pressure
regulator’s hose tting on the cylinder.
with a exible rubber hose in accordance
with the standard, with an 8 mm diameter,
minimum 400 mm in length, maximum 1500
mm in length, rmly secured to the hose
tting with a safety clamp as per the standard.
ATTENTION:
If the appliance is going to be recessed
(class 2 subclass 1), connect it to the gas
supply source using only exible stainless
steel, seamless pipes in accordance with the
standard.
If the appliance is going to be installed free-
standing (class 1) and if you use the exible
rubber hose, it is necessary to follow the
instructions and gures given below (g.19)
On its route, the hose must not touch any parts
where the temperature is more than 9C.
The hose must not be subject to any kind
of torsional stress or tractive force, there
must be no pinched parts or really sharp
bends.
It must not touch anything that can cut,
that has sharp corners, etc.
The whole length of the hose must be easy
to inspect in order to keep a check on its
condition.
It must be replaced within the date printed
on it.
Connection
point
Connection
point
Isolating tap
HOT SURFACE
Hose
assembly
Hose
assembly