Instruction for Use

24
INSTRUCTIONS FOR THE INSTALLER
C
V
20
ADJUSTMENTS
All seal must be replaced by the technician
following any adjustment or regulation.
The adjustment of the reduce rate
(simmer) must be undertaken only with
burners functioning on natural gas
while in the case of burners functioning
on L.P.G, the screw must be locked down
fully (in clockwise direction).
“Primary air adjustment” on hob gas
burners is unnecessary.
TAPS (g. 20)
All gas taps are male cone type with only one
way of passage. The adjustment screw (V) is on
the side of the stem.
Adjustment of the “Reduced rate” position as
follows:
Turn the burner on and place the knob on
the “Reduced rate position (small ame).
Remove the knob of the tap which is attached
by simply applying pressure to the rod.
Insert a small screwdriver (C) into screw (V)
and turn to the right or left the throttling
cone until the ame of the burner is
conveniently regulated to the Low position,
the adjustment screw (V) is over (g. 20) or
on the side of the stem.
Check that the ame does not go out when
the knob is sharply switched from the “Full
on to “Reduced rate positions.
ATTENTION!! This operation can be carried
out also with the front panel tted, but if the
technician nds some diculties to reach the
adjustment screw, remove the front panel
unscrewing the xing screws, which are
positioned in the inferior part of the same.
C
V
21
OVEN THERMOSTAT (g. 21)
Reduced rate adjustment should be carried
out in the following way:
Remove the knob thermostat.
Switch on the oven burner by turning the
relative knob to the Maximum position, then
wait about 10 minutes.
Slowly turn the knob back to the Minimum
position and, using a small screwdriver (C), turn
screw (V) to the right to lower the ame or to
the left to increase it.
The ames must be short for an ecient
Reduced rate setting. They must be stable
to prevent them from accidentally going out
and must be able to stand up to normal oven
door manoeuvres.