Instruction for Use

24
with a exible stainless steel, seamless
pipe in accordance with the standard,
with a maximum 2 metre extension and
seals in accordance with the standard. We
recommend applying the special adapter to
the exible pipe, easily found on the market,
to facilitate connection to the pressure
regulators hose tting on the cylinder.
with a flexible rubber hose in accordance
with the standard, with an 8 mm diameter,
minimum 400 mm in length, maximum
1500 mm in length, firmly secured to the
hose fitting with a safety clamp as per the
standard.
ATTENTION:
• If the appliance is going to be recessed
(class 2 subclass 1), connect it to the gas
supply source using only exible stainless
steel, seamless pipes in accordance with
the standard.
• If the appliance is going to be installed
free-standing (class 1) and if you use
the exible rubber hose, it is necessary
to follow the instructions and the g. 14
given below:
• On its route, the hose must not touch any
parts where the over temperature is than
95°C.
• The hose must not be subject to any kind
of torsional stress or tractive force, there
must be no pinched parts or really sharp
bends.
• It must not touch anything that can cut,
that has sharp corners, etc.
• The whole length of the hose must be
easy to inspect in order to keep a check on
its condition.
• It must be replaced within the date
printed on it.
INSTRUCTIONS FOR THE INSTALLER