T&+1 3 01 Installation hiLtionsand UseMareGuide Model and serkl number plate -(behlndfrontpanel) r Control panel I Control panel Model and serial number AIRCONDITIONERS ModelsACS602 ACS802 ACSlOP ACC602 a-%
Contents Important Safety Instructions. . . . , . . . . Electrical Requlnments .........,.... Receptacle wiring . . . . . . . . . . . . . . . , . . . . Electrical requirements . . . . . . . . . . . , . . . . Elect&al connection . . . . . . . . . . . . . . . . . Instsllatlon Instructions. ............, Installation instructions for models ACS602, ACS602 and ACS102 . . . . . . Installation instructions for model ACC602 . . . . . . . . . . . . . . . . . . . . Operating Instructions ...............
ElectricalRequirements Electrical requirements are different for the two models pictured on the cover, depending on the ampere rating of your unit. The number of amperes is printed on the serial plate, which is attached to the front of the unit behind the front panel. (See diagram on page 12.) Observe all local governing codes and ordinances. Do not, under any circumstances, remove the power supply cord grounding prong.
Eloctrlcal Rsqulramsnts Continusd Electrically grounded metal coid water pipe (removepelnt,etc.) Ground assembly (attach to grounded metal cold water pipe) 7 f 1 Grounded eyelet all receptacle ~‘- 1 t--Gmundlng- Temporary grounding msthod If changing and property grounding the wall recap tacle is impossible and where local codes permit (consuft your electrical inspector), a temporary adapter may bs plugged into the existing P-prong wall receptacle to mate with the 3-prong power supply cord.
1. Unpack mounting parts before installing your air conditioner. Make sure you have all the necessary parts. A normal installation can be made with a screwdriver, saw, small level, pocket knife, tape measure, drill and Ye: VW”and %s” drill bits.
Instdlsth Contlnwd InstmcUoms 4. Attach support bracket (Item 2) loosely to the underside of shelf with either short or long leg down and with end of bracket either toward or away from window, depending upon con&uction and depth of wall and window sill (see diagram). Attach sill bracket (Item 3). Each bracket is attached using one %s” bolt, nut and washers (Items 4,4A, 48 and 4C). Room side t -It=-“‘” Uw screws 5 or 5A 5.
11. Peel backing from seal strip (Item 8) and press it onto side filler frame guides on each side of unit. seal strip Slldlng sash IL . sesl strip 12. Place unit in window by testing unit on shelf. Push unit toward window so side angles are sealing against the side jamb stop (see diagram). Slide the opened window sash firmly to make certain the frame and unit sealing strips are sealing. sod strip 13. Using %I” drill, install locking screws (Item 7).
Mdsngk 16ort66au6a Addwood ushown Add l ngt8 towoodstop 16. For lnstallatlon In windows havlng no side flanges or with wood stops. The flanges (top and two sides) on the air conditioner must mate against companion flanges on the window, not more than %s” (.2 cm) in thickness. On the side with the opened sash, the leading edge of the sash becomes the flange. On the top and jamb side of most metal windows, the flange is there.
Fersonal InJury M Becauss this alr condltloner weighs &out 78 to 75 pounds, it Is recomthat you have somsone help you Install your newunltandthatyoubothuse~llftlng techniques. l This appliance must be Installad according to all appllcabla codes and ordinances. l Handle the air condltloner wlth care. Watch out for the sharp metal flns on ths front and rear tolls. l Do not use the collected water for drlnklng purposes. lt Is not sanitary. Fallum to follow ths above precautkns could result In parsonal InJury.
Inst8lktlon Continued In-s 5. Check the knurled knob screws to see that the top mounting brackets (Item 5) are Mracted to the center of the unit. They must not interfere witft the window frame when the unit is installed. 6. Lift the unit into the window opening and slide it back until the mounting frame comes into contact with the window frame. 7. Replace the bottom mounting brackets (Item 3) by hooking the bracket over the window frame.
Operating. Instructions Startingyourair conditioner l.Setexhaustcont~0I(iiyourunitisso equipped) to CLOSED for maxfmum cooling. 2.ChooseeitherLOCOOLorHICOOLfan speed aetling. LOCOOL . . . . . . . . . . . . . . fors&epklgcomfort HICOOL . . . . . . . . . . . . . . formaxfmumcooflng FANONLY . . . . . . . . . . . . forcim&tfngroomeir whennocoolinglsdealled 3. lbrn the thermostat conb’olto06 (mid-setting). You can a@st the air amWooer cooling performance by-%l* L control to a higher number for IM&UTI cooling.
Cleaningandcaringfor your air conditioner Model and wrlal number Proper use and care of your air condiiner will help ensure lonaer life of the unit and lower operating’costs. Follow these instructions carefully.CalI your Whirlpool servicing dealer for an annual checkup. Cleaning front panel l l ElectrIcal Shock and Flra Hazard Unplug power cord from receptacle before cleaning unlt. Failure to do so could mlt In electrical shock or personal Injury.
Annual maintenance for your air condttloner Your air conditioner needs annual maintenance to help ensure steady, top performance throughout the year. Call the service company recommended by your dealer to: l Inspect and clean the coils and condensate water passages. l Check fan and oil the fan motor. l The compressor is sealed and needs no oiling. Expense of annual inspection is customer’s responsibility. -ORlf you are familiar with electrical appliances, you can do the cleaning and maintenance yourself.
Olllng the fan motor Electrlcal Shock Hazard Disconnect power cord from receptacle before oiling motor. Fallure to do so could result In personal InJury. 1. Oil the fan motor per instructions on the motor. To add oil, pull out the oil hole plug at each end of the motor (see diagram). An easy-to-use one-ounce capsule of especially recommended oil (Part No. 10943) can be ordered from your Whirlpool servicing dealer, or use SAE X20 non-detergent oil. 2. Replace the plug to keep dirt from motor bearings. 3.
If YouNeedServiceOrAssistance Wesuggestyoufollow thesesteps: 1. gefore calling for assistance... Performance problems often result from little things you can Lnd and fix your& without tools of any kind. Air oendWonor won? run: Is unit plugged into a live circuit with proper voltage? l Is swttch turned on? l Is thermostat set correctly? l Has a fuse blown or a circuit breaker tripped? l Has the local power failed? l 3. if you need service?.. Whirtpoolhasanationwide - workof-Whi& vkf 01 ssnriceannpaniw3.
Whirlpool”RoomAir Conditioner Warranty LENGTH OF WARRANTY FULL OWE-YEAR WARRANTY From Date of Purchase 1 WHIRLPOOL WILL PAY FOR FSP@replacement parts and repair labor to correct defects in materials or workrnanshib. FULLFIVE-YEAR WARRANTY From Date of Purchase FSP replacement parts and repair labor to correct defects in materials or workmanship in the sealed refrigeration system. These parts are: 1. Compressor 4. Drier-Strainer 2. Evaporator 5. Connecting Tubing 3.