Installation

R
R
R
PLUMBING OPTIONS
Option 1 and Standpipe Ø38mm with Air Gap.
Option 2 with Waste Disposal.
Standpipe Ø38mm with Air Gap.
PLEASE NOTE: It is NOT recommended to connect the
to any part of the Waste Disposal System.
Option 3 using Sink Trap with Drain Hose Joiner.
NOTE: Prefinished Model is shown. There is no variation in plumbing
between Prefinished products and Integrated products. Option 1
and 2 are the preferred options. Options 1 & 2 or use of a Dual
Inlet
Airgap satisfy Kosher requirements.
DOUBLE MODEL
SERVICE'S SPECIFICATION
*For an Integrated the product depth is specified with an
18mm Integrated Door Panel thickness.
Water Connection
Recommended COLD (Maximum 60°C).
3/4 " BSP (GB20) to suit flat washer.
Water Softener Models
Refer to your User Guide on how to set up your water
softener.
Water Pressure
Drain Connection
Drain Hose Joiner to suit
Ø19mm ± 2mm waste tee.
Electrical Connection
230-240 VAC power outlet
9Amps Minimum.
Toe Kick Depth
Prefinished
50-65mm; Integrated 67mm less the Toe Kick Panel
thickness (Minimum Panel thickness using the supplied screws is 9mm).
# Door Front Height
Prefinished
717.5mm; Integrated 717.5mm minimum.
Length of Services
Drain hose - 2250mm
Inlet hose - 1750mm
Power supply cord - 1965mm
NOTE: Services approximately exit product
189mm from left; 550mm from front; 793mm from top.
R
R
(page 3 of 8)
THE CAVITY
NOTE: All depth measurements are taken from the front
face of the adjacent cabinetry.
Ensure the edges of the services hole are smooth or
covered.
+
Min thickness of cavity
sides is
16mm
90°
Ø50mm
services hol e
can be either
side, immediatel y
adjacent to
corner
+
+
600mm
580mm
throughout cavity
820mm-880mm
82.5mm
+
97mm
505mm
+
+
640.5mm
14mm
From front
of cabinetry
These marks indicate mounting tab
crew locations (refer to step 1 page 5)
+
*
R
PLUMBING OPTIONS
Option 1 and Standpipe Ø38mm with Air Gap.
Option 2 with Waste Disposal.
Standpipe Ø38mm with Air Gap.
PLEASE NOTE: It is NOT recommended to connect the
to any part of the Waste Disposal System.
Option 3 using Sink Trap with Drain Hose Joiner.
NOTE: Prefinished Model is shown. There is no variation in plumbing
between Prefinished products and Integrated products. Option 1 and
2 are the preferred options. Options 1 & 2 or use of a Dual
Inlet
Airgap satisfy Kosher requirements.
SINGLE MODEL
SERVICE'S SPECIFICATION
*For an Integrated the product depth is specified with an 18mm
Integrated Door Panel thickness.
Water Connection
Recommended COLD (Maximum 60°C).
3/4 " BSP (GB20) to suit flat washer.
Water Softener Models
Refer to your User Guide on how to set up your water
softener.
Water Pressure
Drain Connection
Drain Hose Joiner to suit
Ø19mm ± 2mm waste tee.
Electrical Connection
230-240 VAC power outlet
4.5Amps Minimum.
Weight
Full 42kg Prefinished
Empty 28kg Prefinished
Length of Services
Drain hose - 2250mm
Inlet hose - 1750mm
Power supply cord - 1965mm
NOTE: Services approximately exit product
189mm from left; 550mm from front;
393mm from top.
(page 4 of 8)
THE CA
VITY
NOTE: All depth measurements are taken from the front
face of the adjacent cabinetry.
NOTE: To align drawer front to adjacent cabinetry, the
product to counter top clearance can be increased
from 3mm.
Ensure the edges of the services hole are smooth or covered.
Cabinetry must
not extend beyond
cavity base
*
505mm
+
Min thickness
of cavity
sides is 16mm
90°
Ø50mm services hole can be either side,
immediately adjacent to corner
+
600mm
580mm
throughout cavity
410mm
67mm
97mm
+
+
These marks indicate mounting tab
screw locations (refer to step 1 page 5)
+
#
Maximum Minimum
Water Softener Models 1000kPa (145 p.s.i.) 100kPa (14.5 p.s.i.)
Other Models 1000kPa (145 p.s.i.) 30kPa (4.3 p.s.i.)
Maximum Minimum
Water Softener Models 1000kPa (145 p.s.i.) 100kPa (14.5 p.s.i.)
Other Models 1000kPa (145 p.s.i.) 30kPa (4.3 p.s.i.)
1Gb00079 28-11-2002 18:50 Pagina 2