Installation

R
R
R
7 CONNECTING THE INLET HOSE & POWER SUPPLY
Connect the Inlet Hose to the water supply. Ensure the sealing
washer is in place. The hose coupling must be tightened a further
half turn after seal contact. TIP - Turn the water valve ON to check
for any leaks.
Ensure there is a power outlet in reach of the power supply cord. If
there is not a suitable outlet available then have one installed by a
qualified electrician.
NOTE: SINGLE MODELS DO NOT HAVE A TOE KICK TO INSTALL.
PROCEED TO STEP 11 FINAL CHECK LIST.
17
18
DO NOT plug the product in at this stage.
DO NOT cut the inlet hose.
18
17
8 MEASURING THE TOE KICK
DOUBLE MODELS ONLY
Partially open the bottom drawer. Turn
Prefinished Toe Kick upside down and hold
vertically against the bottom edge of the
Tub side (not the drawer front).
Mark the position of the bottom edge of the
Tub side on the Toe Kick.
Choose the nearest groove to the pencil mark
which will result in the shortest Toe Kick.
19
9 TRIMMING THE TOE KICK
DOUBLE MODELS ONLY
On the chosen groove cut down the vertical ribs at the centre and
the ends using a knife. Cut along full length with a knife. Turn Toe
Kick over, bend and then cut from front. Sand or scrap bottom edge
to remove rough patches.
To avoid a cutting hazard remove all
sharp edges after trimming.
Remove Toe Kick tabs by snapping them off.
20
21
IMPORTANT - Before cutting ensure the Toe Kick is positioned on a
wooden chopping board to avoid damage to surrounding area.
20
22
21
22
10 FITTING TOE KICK TO PRODUCT
DOUBLE MODELS ONLY
Partly open bottom drawer. Position Toe Kick
behind door and slide onto the mounting rails on
the underside of tub.
Close bottom drawer, check if flush with adjacent
cabinetry. If required open drawer and adjust.
Note: Clearance between Toe kick and floor must
be 12mm minimum.
When Toe Kick is in position, open bottom drawer
and gently fasten the Toe Kick screws, on each
side.
23
24
23
24
DO NOT over tighten screws.
Overtightening will damage
the plastic mounting detail.
11 FINAL CHECK LIST - DOUBLE & SINGLE MODELS
Ensure product is level, securely fastened to the cabinetry and opens and closes
freely. The must be free to close with no resistance from the
cabinetry.
Ensure inlet hose to valve connection is tightened a further half turn after seal
contact.
Ensure any knockouts or plugs in drain connection have been drilled out and
drain connection has been made.
Turn ON the power and water supply.
The should beep and light up.
Open the drawer(s) and check operation of Wash Programme Control Panel and
check the sprayarm(s) are in place and free to rotate.
On the Wash Programme Control Panel select Rinse and close the drawer(s). Start
the programme by pressing the Start/Pause button.
After the Rinse programme has finished, ensure machine has run and drained
correctly.
Check water supply and drainage connection for leakage.
Repeat for each Drawer.
LEAVE ALL LITERATURE WITH CUSTOMER.
TROUBLE SHOOTING
Excessive water remaining above the filter plate,
after the rinse cycle; check for kinked drain hoses or
blocked waste connection.
No water supply; check water is connected, ON and
there is water pressure.
does not light up when the tub is
opened; ensure power is connected and is switched
ON.
Water around water supply and drainage connections
- check connections, existing plumbing and hoses for
leaks.
If a fault occurs, consult the Fault Code Section of
the User Guide.
If unable to resolve, contact your Customer Care
Centre.
12 CUSTOMER SUPPORT
(page 7 of 8)
(page 8 of 8)
Remove all sharp edges
Bottom edge
of tub side
19
If after carrying out the above checks the malfunction persists or appears again, turn the appliance off and turn off the
water supply tap, then call our After-Sales Service (see guarantee).
Before contacting our After-Sales Service, take note of the following:
• The nature of the fault.
• The appliance type and model.
• The service code (the number indicated on the adhesive rating plate).
5019 102 00079
Whirlpool is a registered trademark of Whirlpool USA
1Gb00079 28-11-2002 18:50 Pagina 4