Fuse replacement and thermal relay rearm
i The fuses (A) and the thermal relay (B) are
in the upper part of the blast chiller. To access
these just open the control panel (C) by loosening
the two screws (D) positioned in the lower part of
the control panel and rotating it upwards. After
opening, make sure that it does not fall back
down.
7. TROUBLESHOOTING
The information shown below aims to help with
the identification and correction of any anomalies
and malfunctions which could occur during use.
Some of these problems can be resolved by the
user. For the others, precise skill is required and
they must therefore only be carried out by
qualified staff.
Problem Causes Solutions
Check the power supply cable.
Check fuses.
No voltage
Check the correct connection of the
appliance.
The refrigerator unit does not start
Other causes
@ If the problem persists,
contact the after-sales centre.
Room too hot Air the environment
Dirty condenser clean the condenser
Insufficient door sealing check the gaskets
Insufficient quantity of
refrigerant gas
@ Contact the after-sales
centre.
Condenser fan at a standstill
@ Contact the after-sales
centre.
The refrigerator unit functions
continuously, cooling insufficiently
Evaporator fan standstill
@ Contact the after-sales
centre.
B
C
D
A
Rearm the heat relay
using the grey button