Instruction for Use

15
ENGLISH
GB
Problem Causes Solutions
Probe faulty
@ Contact the after-sales
centre.
The refrigerator unit does not stop
Circuit board fault
@ Contact the after-sales
centre.
Carry out a defrosting cycle possibly
with the door open.
Presence of ice inside the
evaporator
@ If the problem persists,
contact the after-sales centre.
Appliance noise Persistent vibrations
check there is no contact between
the appliance and other objects
inside or outside
7.1. Faults Display
Problem Causes Solutions
"E0" flashes on the display and
the buzzer emits an intermittent
noise
(compartment probe error)
"E1" flashes on the display and
the buzzer emits an intermittent
noise
(evaporator probe error)
"E3" flashes on the display and
the buzzer emits an intermittent
noise
(needle probe error)
Ø The type of probe is
incorrect.
Ø The probe is faulty.
Ø The probe circuit board
connection is incorrect.
Ø The temperature detected
by the probe is out of the
limits accepted by the
compartment probe in use
@ Contact the after-sales
centre.
Ø Check that the compartment
probe is the PTC type.
Ø Check the integrity of the
compartment probe.
Ø Check correctness of the
instrument - probe connection.
Ø Check that the temperature in
proximity of the compartment
probe is not out of the accepted
limits
"dFL" flashes on the display and
the buzzer emits an intermittent
noise
The evaporator fan deflector
has been opened.
Close the evaporator fan deflector.
@ If the problem persists,
contact the after-sales centre.
"HP" flashes on the display and
the buzzer emits an intermittent
noise
(high pressure- Compressor
Circuit Breaker alarm)
Ø The pressure detected by
the maximum pressure
switch is higher than the
limit value.
Ø The absorption of the
compressor has exceeded
the envisioned maximum
limit.
Ø Air the environment.
Ø Clean the condenser
Ø Check that the fans function
correctly.
@ If the problem persists,
contact the after-sales centre