Instruction for Use

17
ENGLISH
GB
! ATTENTION: the appliance requires the
minimum functioning spaces, as shown in the
attachments.
The defrosting water and the water that forms at
the bottom of the refrigerating compartment
during operation or during periodical internal
cleaning must be drained through a prearranged
hose with a minimum diameter 3/4 connected to
the hose at the bottom of the chiller.
A drain trap should also be guaranteed. The drain
must be in compliance with Standards in force.
8.3. Electric Power Supply Connection
Connection must be carried out by authorised and
qualified staff, respecting the current laws
regarding the subject and using appropriate
prescribed material.
i Before connecting the appliance to the
electric mains, check that the voltage and the
frequency correspond to the data stated on the
registration plate applied on the rear of the
appliance.
iThe appliance is supplied with an operating
voltage of 230V 1+N~ 50 50Hz. On request, it is
possible to have appliances with different
voltages.
! Before connection, ensure the presence of a
relevant differential switch with adequate power in
the mains power supply, upstream from the
appliance, in order to protect the appliance from
overloads or short circuits
8.4. Inspection
The appliance is delivered in conditions such that
it can be started-up by the user.
This functionality is guaranteed by passing the
tests (electric inspection - functional inspection,
appearance inspection) and relative certification
through the specific attachments.
At least the following should be checked after
installation:
Ø Check the electric connections.
Ø Check the functionality and efficiency of
drains.
Ø Check that there are no tools or materials
left in the appliance that could jeopardise
its functionality or even damage the
machine.
Ø Have the appliance perform at least one
complete chill blasting/shock freezing
cycle