Instruction for Use

6
ENGLISH
GB
i All maintenance interventions that require
precise technical skill or particular ability must be
performed exclusively by qualified staff.
! When using the appliance, never obstruct the
air inlet when the appliance is on, so as not to
compromise its performance and safety.
! Never stretch the power cable.
In order to guarantee hygiene and protect the
foodstuffs from contamination, the elements that
come into direct or indirect contact with the
foodstuffs must be cleaned very well along with
the surrounding areas. These operations must
only be performed using detergents that can be
used with foodstuffs, avoiding inflammable
products or those that contain substances that are
harmful to personal health.
In the case of prolonged inactivity, as well as
disconnecting all the supply lines, it is necessary
to accurately clean all internal and external parts
of the appliance.
4.1. Safety Devices
During the running of appliance, some control
devices may activate and govern the correct
running of the machine. In other cases, they may
deactivate parts or the whole machine, to put the
appliance in safe conditions. Main controls are
described below.
Door micro switch
If the door is opened, the
magnetic switch placed on the control board
opens and, during blast-chilling or shock-freezing,
evaporator fans go off and a warning message
appears on the display at the same time. This
condition may also be determined when the door
is not perfectly aligned to or near the control
board: in this case with the machine in the STOP
phase, no cycle may be started.
High pressure safety pressure switch
In the event of room
conditions or functional anomalies, which cause
the refrigerating circuit to exceed the maximum
pressure values, the MAX safety switch is
activated, stopping the machine. When an
acceptable pressure value is reset, it is possible to
run the machine.
Protective Fuses
Some protection fuses in the general power
supply line are activated in case of overload.
Other fuses are prepared for the evaporator fans
Evaporator Fan Micro switch
If the deflector is opened to
inspect the evaporator or fans, this micro switch
positioned on the evaporator deflector,
deactivates machine functioning. Closure of the
deflector with the successive disappearance of
the alarm on the display, restores normal machine
functioning.