Setup guide

LC3000 LAUNDRY READER INSTALLATION GUIDE
D OCUMENT 1135 REV 03
PRINTED OCTOBER 6, 2009 1-7
PREPARE ENCLOSURE
The Reader can be mounted flush to the wall with
wiring behind the wall; or it can be surface-
mounted with wiring in conduit exterior of the wall.
Before mounting the enclosure, remove knockouts
necessary for routing wires and/or attaching
conduits. Remove only the knockouts required for
your installation.
AC power knockouts accept 1/2'' conduit fittings.
All other knockouts accept 3/4'' conduit fittings.
Flush-mount: route machine wires, if wired,
through the 3'' x 3'' cutout.
Surface-mount: Remove conduit knockouts
on the top and bottom of the enclosure for
routing wire to machines.
Two power knockouts are provided in the upper
right.
Flush-mount: Remove the knockout on the
back side.
Surface-mount: Remove the knockout on the
top.
Install the LC3000 Enclosure
5 Inside the LC3000, remove the power supply cover to
access the upper right mounting hole.
Protect power supply from debris while mounting the
enclosure.
6 Secure enclosure to a wall using hardware appropriate to
wall material.
Mounting holes accept up to 1/4'' hardware.
Disconnect external AC power when installing wiring.
7 Strip back insulation on AC wire .28" to prevent bare wire
exposure when installed in AC terminal block.
ACMAIN
Mount
Mount
AC power knockouts
machine wires
use side
knockouts
only if
surface
mounting
Figure 1-3 Mounting & Knockouts
flush-mount
Figure 1-4 Power Installation