Setup guide

LC3000 LAUNDRY READER INSTALLATION GUIDE
D OCUMENT 1135 REV 03
PRINTED OCTOBER 6, 2009 1-19
2 Route the 4-conductor cable from the LCM20 into the laundry machine for connection to the LCI.
3 Attach female connectors from the hardware kit to the machine end of the 4-conductor cable.
4 Insert the LCI male bullet connectors into the female connectors of the 4-conductor cable (white to
white, black to black, etc.) see:
Figure 1-15.
Stacked Machine: connect the two-wire harness to the black and green wires, as shown.
5 Install the LCI into the machine circuit board’s six-pin Molex (see: Figure 1-16), and if a stacked dryer,
adjacent 2-pin Molex.
6 Use the wire ties and wire tie blocks included in the hardware kit to dress the wires, and replace the
laundry machine operator console.
7 Terminate the 4-conductor cable at the LCM20 1 x 4 terminal block(s).
Switch the green and white wires if the signals do not correspond to the machines as labeled.
1
2
3
4
1
2
3
4
white
black
red
black
red
black
white
6-pin Molex
Stacked Dryer
Maytag
Laundry Controller
Multiplexer (LCM20)
white
red
black
green
green
5
6
1
2
1
2
3
4
Figure 1-16 Maytag Stacked Machine
or equivalent 4-conductor cable
BELDEN 8723