6 Verify communication between the Bridge module and LC3000 Reader using the status LED. The LED
should be blinking approximately once every second. Install the cover onto the plastic enclosure to
enclose the cable and module.
The wire antenna must be slightly arced when the cover is installed.
For Troubleshooting and Operation Information, See: Wireless Module Troubleshooting
and Operation (page 30)
LAUNDRY WIRELESS INTERFACE MODULE (LWI) INSTALLATION
Configure the LWI Module
Before installing an LWI module in a washer or dryer, the module must be configured. Configuring consists
of assigning a network ID and machine ID. These two parameters make each LWI module unique within
the wireless network, ensuring only a single module responds to a command from the Bridge.
The network ID can be assigned the values 1 through 6. This number must be identical to the number
assigned to the Bridge. This value sychronizes the communication between the Bridge and the LWI
module by selecting the appropriate frequency hopping table.
The machine ID can be assigned the values 1 through 60. This number corresponds to the unique number
assigned to each washer/dryer located in the Laundry Center. Each washer and dryer must be labeled with
the machine number. The number should be clearly visible to patrons using the Laundry Center.
For Stack Dryers, a single module is used to support both upper and lower machines. The top machine
must be assigned the odd number, the lower machine the even number. The even number must
always be 1 more than the odd number. Thus valid pairs are (1, 2), (3, 4) and (29, 30) and so forth. An
invalid combination would be (28, 29). This would be considered as separate machines at the host
software level. The assignment of the top machine being an odd number is the result of the electrical
connection between the wiring harness and module.
It is imperative the LWI module, once programmed with the machine ID, be installed in the
corresponding labeled laundry machine. A label is provided on the side of the module, to allow the
installer to write the machine ID programmed into the module.
1 Apply power the LC3000 Reader and make sure it is online.
2 Install the configuration cable (p/n 044-042-043) into the RJ-12 jack labeled LWI CONFIG.
This cable is supplied with the LE3/BRIDGE.