Instruction for Use

N C
M Y
INSTALLATION
Adjustment to different types of
gas
If a different type of gas from the one indicated
in the plate is used, the cooking hob must be
adapted to it.
1. The gas nozzles must be changed by
Customer Service or a qualified technician.
Nozzles not supplied with the appliance must
be ordered from Customer Service.
2. Connect the cooking hob to the gas shut-off
valvebymeansofapipesuitableforthetype
of gas used, in compliance with current local
regulations.
3. Adjust the minimum setting of the taps.
Note: when liquid petroleum gas G 30/G 31 is
used, the minimum gas setting screws must be
tightened as far as they will go.
Replacing the injectors (see table in
enclosed product description sheet)
1. Remove grids
.
2. Extract burners
.
3. Using a socket spanner of the appropriate size
unscrew the injector to be replaced.
4. Replace it with the injector suitable for the
new type of gas.
5. Re-assemble the injector in
.
Adjusting minimum gas setting
of taps
To ensure that the minimum setting is correctly
adjusted, remove knob and proceed as follows:
x tighten (-) to reduce the height of the flame;
x loosen (+) to increase the height of the flame.
The adjustment must be performed with the tap
in minimum gas setting position (small flame) .
19