Instruction for Use

43
Electrical Connection
To be done before connection
to the electricity supply.
The appliance must be
installed by a qualified
technician who is fully aware
of current safety and
installation regulations and
who will comply with these
regulations.
Make sure that the voltage
indicated on the rating plate
corresponds to the voltage in
your home.
Regulations require that the
appliance is earthed; for this
reason all conductors and
earth conductor must be of
the appropriate size.
Make sure the earth
connection is made correctly.
The manufacturer declines all
liability for injury to persons
and animals or damage to
property resulting from
failure to observe the above
regulations.
For the electrical connection
use a HO5RR-F type cable as
indicated in the table below:
If the hob is already
equipped with a power
supply cable, see the
electrical connection
diagram shown in the
Product Description Sheet.
An all-pole disconnect
switch with minimum
contact gap equal to or
greater than 3 mm must
be used to install the hob.
Attention: the power supply
cable must be long enough to
allow the hob to be removed
from the worktop and must
be positioned so as to avoid
damage or overheating
caused by contact with the
base.
Terminal block
connections
Note: The earth wire (yellow/
green) must be connected to
the terminal with the symbol
and must be longer than the
other wires.
Strip approx. 70 mm of
sheath from the power
supply cable (B).
Strip approx. 20 mm of
sheath from the wires First
insert the cable (max 14
mm diameter) in the cable
clamp and connect the
wires to the terminal block
as indicated in the diagram
printed on the bottom of
the hob.
Secure the power supply
cable (B) by means of the
cable clamp.
Fit and secure the cover (A).
After the initial electrical
connection or whenever
turning the hob on/off, a
symbol, (for example E-00,
E-01, E-02) will be displayed
for a few seconds.
Voltage Conductors
(number and size)
230 V
3 X 2.5 mm
2
min.
230 V 3
4 X 2.5 mm
2
min.
400 V 2N
4 X 2.5 mm
2
min.
400 V 3N
5 X 1.5 mm
2
min.
4gb61581a.fm5 Page 43 Friday, February 28, 2003 2:25 PM