Instruction for Use

Type of gas
used
G30
G25
INJECTORS TABLE
min. rat. max.
ELECTRIC SUPPLY:
230 V ~ 50 Hz
G31
20 25 30
25 30 35
25 30 35
G25.3
G20
17 20 25
20 25 30
1 PB 2C - 1R - 2SR -1AUX
1 PB 2C - 1R - 2SR -1AUX
1 PB 2C - 1R - 2SR -1AUX
1 PB 2C - 1R - 2SR -1AUX
1 PB 2C - 1R - 2SR -1AUX
G25 25 mbar
G25.3 25 mbar
G20 20 mbar
G30 30 mbar
G31 30 mbar
11.00
11.00
11.00
11.00
11.00
1218 l/h
1192 l/h
1047 l/h
800 g/h
786 g/h
8.187
8.187
9.52
30.94
30.94
CATEGORY II2L3B/P
NATURAL GAS
(Methane)
LIQUEFIED
PETROLEUM GAS
(Butane)
Model configuration
5 BURNERS
Total rated
consumption
Air required (m³) for
burning 1 m³ of gas
Injector
marking
Rated thermal
flow rate
kW
Rated
consumption
Rated heat
capacity
kW
Gas pressure
mbar
LIQUEFIED
PETROLEUM GAS
(Propane)
Type of gas
used
Rated thermal
flow rate kW
Type of
burner
NATURAL GAS
(Methane)
NATURAL GAS
(Methane)
Power Burner
Rapid
Semi-rapid
Auxiliary
Power Burner
Rapid
Semi-rapid
Auxiliary
Power Burner
Rapid
Semi-rapid
Auxiliary
Power Burner
Rapid
Semi-rapid
Auxiliary
Power Burner
Rapid
Semi-rapid
Auxiliary
140 T2A
130 T2C
100 T2
78 T2B
140 T2A
130 T2C
100 T2
78 T2B
144 B
115 Y
97 Z
72 X
93 P
86
65
50
93 P
86
65
50
3.50
3.00
1.75
1.00
3.50
3.00
1.75
1.00
3.50
3.00
1.75
1.00
3.50
3.00
1.75
1.00
3.50
3.00
1.75
1.00
388 l/h
332 l/h
194 l/h
111 l/h
379 l/h
325 l/h
190 l/h
108 l/h
333 l/h
286 l/h
167 l/h
95 l/h
254 g/h
218 g/h
127 g/h
73 g/h
250 g/h
214 g/h
125 g/h
71 g/h
1.55
0.60
0.35
0.35
1.55
0.60
0.35
0.35
1.55
0.60
0.35
0.35
1.90
0.60
0.35
0.35
1.90
0.60
0.35
0.35
WOK ADAPTER (if present)
The WOK adapter has to be used only on the Power Burner [with multiple crown]
Appearence of your product can be slightly different from the drawing.