Instruction for Use

GB11
The hood is designed for use in “Extractor version or in “Filter version”.
Extractor version
Fumes are extracted and expelled to the outside through an exhaust pipe (not supplied) fixed to the hood exhaust pipe connector B.
Depending on the exhaust pipe purchased, provide for suitable fixing to the exhaust pipe connector.
Important: If already installed, remove the carbon filter/s.
Filter version
Air is filtered through the carbon filter/s and recycled into the surrounding environment.
Important: check that air recirculation is facilitated.
Important: If the hood does not have a carbon filter/s, order one/them and fit it/them before use.
The instructions below, to be carried out in the order in which they are numbered, refer to the figures (with the same step numbers) given on the last pages of
this manual.
Note: Some instructions differ depending on the product width or hood box height, in which case installation differences are given in the text and in the figures.
1. Mark a line on the wall, up to the ceiling, corresponding to the centre line.
2. Place the drilling template against the wall (fix it with adhesive tape): the vertical centre line printed on the template must match the centre line drawn on
the wall, and the bottom edge of the drilling template must match the bottom edge of the hood.
Drill a hole.
3. Remove the drilling template and insert plugs and screws as indicated.
4. Tighten a little
5. Place the flue support bracket on the wall, against the ceiling. Drill and insert the wall plugs as indicated. Fix the bracket.
6. Extractor Version only - rear exhaust: Make a hole in the rear wall for the exhaust pipe.
7. Extractor Version only - exhaust towards the ceiling: Make a hole in the ceiling for the exhaust pipe.
8. Prepare the connection to the household electrical system.
9. Filter Version only: Fix the deflector to the flue support bracket.
10. Remove the grease filter/s.
11. Remove the tape fixing the control electronics box to the motor body.
Note: the drawing is only for reference, the box may be temporarily fixed to other sides of the motor body.
12. Hook the hood to the wall.
13. Adjust the hood horizontally.
14. Adjust the distance between the hood and the wall.
15. Mark the hole/s for final fixing of the hood as indicated.
16. Remove the hood from the wall.
17. Drill and insert the wall plugs as indicated.
18. Rehook the hood to the wall.
19. Secure the hood to the wall with screws as indicated.
20. Raise the electrics box to a vertical position.
21. Tighten down the already partially tightened screws fixing the box to the motor body.
22. Insert the power cable in its special place.
23. Secure the cable to the cable clamp.
IMPORTANT: This operation is compulsory. It will prevent accidental disconnection of the power cable.
Carry out the connection to the household electrical system.
24. Connect the fume exhaust pipe to the collar; the pipe must be run towards the outside (extractor version) or towards the deflector (filter version).
25. Fit the flues in place over the hood, completely covering the extractor unit.
26 Pull out the upper section and fix the flues with the screws as indicated.
27. Install the carbon filter (Filter Version only, refer to section Maintenance - Active carbon filter - Fitting the carbon filter) and re-fit the grease
filter(s).
Check the hood operation, referring to the hood description and use section.
EXTRACTOR OR FILTERING HOOD INSTALLATION