Instruction for Use

5019 318 33312
INSTALLATION - ASSEMBLY INSTRUCTIONS
The hood is designed for use in “Extractor version” or in “Filter version
Extractor Version
fumes are extracted and expelled to the outside through a fumes exhaust hose (not supplied) fixed to the collar of the hood.
In accordance with the exhaust hose purchased, provide a suitable fixing system to secure it to the collar.
Important: If already installed, remove the carbon filter/s.
Filter Version
Air is filtered through the carbon filter/s and recycled into the surrounding environment.
Important: check that air recirculation is facilitated (to this end, carefully follow the instructions given in the installation
handbook)
Important! If the hood does not have a carbon filter/s, order one/them and fit it/them before use.
Preliminary information for installing the hood:
Disconnect the power supply at the domestic main switch before carrying out electrical connections. Expansion plugs are
provided to secure the hood to most types of ceilings. However, a qualified technician is needed to make sure that the plugs
are suitable for your ceiling. The wall/ceiling must be strong enough to take the weight of the hood. Remove the grease filter/s.
1. Using a pencil, draw the centre line on the wall up to the ceiling to facilitate installation operations.
2. Apply the drilling template to the wall: Align the vertical centre-line on the drilling template with the centre-line drawn on
the wall. The template’s bottom edge represents the bottom edge of the hood.
3. Place the lower support bracket on the hole diagram so that it matches the dotted rectangle, mark the two external holes
and drill.
Note: Drill all the holes indicated on the template: the top 2 holes are for hanging the hood and the bottom holes
(generally 1 central or 2 side holes) are for fixing it securely to the wall.
Remove the hole diagram, insert the wall plugs and fix the hood support bracket with two 5 x 45 mm screws.
4. Fit the flue support bracket “G” to the wall and against the ceiling, use the support bracket as a hole diagram (if present,
the small slot on the support must match the line drawn on the wall ), mark 2 holes with the pencil then drill the holes
(Ø 8 mm) and finally insert 2 plugs.
5. Fix the flue support bracket to the wall with two 5 x 45 mm screws.
6. Hook the hood to the lower bracket.
7. Adjust the distance between the hood and the wall.
8. Adjust the hood horizontally.
9. Fix the hood securely to the wall (ABSOLUTELY NECESSARY!!).
10. Connect an exhaust pipe (pipe and clamps are not supplied and must be bought separately) to the collar located above the
extraction motor unit.
For extractor operation, connect the other end of the exhaust pipe to the home discharge device. For filter operation, fix
the deflector F to the flue support bracket G and connect the other end of the exhaust pipe to the deflector collar F.
11. Insert the steam deflector and secure it to the supports (11b) on the extractor unit with 2 bushings and 2 screws (11a).
12. Make all necessary electrical connections.
13. Fit the flues over the extractor unit, engaging them in their seat above the hood.
14. Slide the top section of the flue and secure it with 2 screws (14a) to the flue support bracket “G” (14b).
Refit the grease filter/s and check for correct hood operation.
FIN
S N DK
GB