Instruction for Use
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: if the distance “A” between the wall cabinets
is between 600 mm and 680 mm, the height “B” must
be a minimum of 520 mm.
if the distance “A” between the wall cabinets is greater
than the width of the hob, the height “B” must be a
minimum of 400 mm.
Before installing a hood above the hob please refer to
the hood instructions which specify the correct distance.
In case of installation of an oven under the hob, please
refer to the separate oven instructions.
+3H2II YROGETACELBAT SROTCEJNI
Type of gas used Type of burner Injector
marking
Rated thermal
ow rate
Rated
consumption
Reduced heat
capacity
Gas pressure
mbar
.xam.tar.nimWkWk
NATURAL GAS
(Methane) G20
17 20 25
LIQUEFIED
PETROLEUM GAS
(Butane) G30
20 28-3035
LIQUEFIED
PETROLEUM GAS
(Propane) G31
25 37 45
Type of gas used Model conguration
5 BURNERS
Rated thermal
owrate (kW)
Total rated
consumption
Air required (m
3
) for
burning1m
3
of gas
G20 20 mbar 2 R - 2 SR - 1 AUX 10.30 981 l/h9.52
G30 28-30 mbar 2 R - 2 SR - 1 AUX10.30 749 g/h30.94
G31 37 mbar 2 R - 2 SR - 1 AUX10.30 735 g/h23.80
ELECTRIC SUPPLY: 230 V ~ 50 Hz
Rapid 115Y 3,00 286 l/h 0,75
Semi-Rapid 95Z 1,65 157 l/h 0,40
Auxiliary
72X 1,00 95 l/h 0,40
Rapid 85 3,00 218 g/h 0,75
Semi-Rapid 63 1,65 120 g/h 0,40
Auxiliary
50 1,00 73 g/h 0,40
Rapid 85 3,00 214 g/h 0,75
Semi-Rapid 63 1,65 118 g/h 0,40
Auxiliary
50 1,00 71 g/h 0,40