Instruction for Use

DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: if the distance “A” between the wall cabinets is between
600 mm and 680 mm, the height “B” must be a minimum of 520 mm.
if the distance “A” between the wall cabinets is greater than the width
of the hob, the height “B” must be a minimum of 400 mm.
Before installing a hood above the hob please refer to the hood
instructions which specify the correct distance. In case of installation
of an oven under the hob, please refer to the separate oven instructions.
+3H2II YROGETACELBAT SROTCEJNI
Type of gas used Type of burner Injector
marking
Rated thermal
ow rate
Rated
consumption
Reduced heat
capacity
Gas pressure
mbar
.xam.tar.nimWkWk
NATURAL GAS
(Methane) G20
Rapid129 B3.00286 l/h0.60
17 20 25Semi-rapid971.65157 l/h0.35
Auxiliary74 B1.0095 l/h0.30
LIQUEFIED
PETROLEUM GAS
(Butane) G30
Rapid863.00218 g/h0.60
20 28-3035Semi-rapid651.65120 g/h0.35
Auxiliary501.00 73 g/h0.30
LIQUEFIED
PETROLEUM GAS
(Propane) G31
Rapid863.00214 g/h0.60
25 37 45Semi-rapid651.65118 g/h0.35
Auxiliary501.00 71 g/h0.30
Type of gas used Model conguration
5 BURNERS
Rated thermal
owrate (kW)
Total rated
consumption
Air required (m
3
) for
burning1m
3
of gas
G20 20 mbar 2 R - 2 SR - 1 AUX 10.30 981 l/h9.52
G30 28-30 mbar 2 R - 2 SR - 1 AUX10.30 749 g/h30.94
G31 37 mbar 2 R - 2 SR - 1 AUX10.30 735 g/h23.80
ELECTRIC SUPPLY: 230 V ~ 50 Hz