Instruction for Use

AKT 300 PRODUCT DESCRIPTION SHEET
GB
5019 319 62035/A
To get full satisfaction from the hob, please read these instructions carefully and keep them for future consultation.
FR
LIGHTING THE BURNERS
To ignite one of the burners, turn the relative knob anti-clockwise to the maximum flame setting .
Press the knob against the control panel to ignite the burner.
PRATICAL ADVICE FOR USING THE BURNERS
For better burner performance, please stick to the following
rules:
- Use pots and pans that fit the burners (see table on the
right).
- Only use flat-bottomed pots and pans.
- Use the correct amount of water for cooking foods and
keep the pot covered.
1.
Removable pan grid
2.
Semi-Rapid Burner
3.
Rapid Burner
4.
Semi-Rapid Burner control knob
5.
Rapid Burner control knob
SYMBOLS
Tap closed
Maximum flame
Minimum flame
Burner Pot Ø
rapid
from 24 to 26 cm
semi-rapid
from 16 to 22 cm
DIMENSIONS AND DISTANCES TO BE MAINTAINED (mm)
NOTE: In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct
distance.
INJECTOR TABLE CATEGORY II2E+3+
ELECTRIC SUPPLY: 230 V - 50 Hz
Type of gas used Type of burner Injector
marking
Rated thermal
flow rate kW
Rated
consumption
Reduced heat
capacity kW
Gas pressure (mbar)
min. rat. max.
NATURAL GAS
(Methane) G20
rapid
semi-rapid
128
95
3.00
1.65
286 l/h
157 l/h
0.60
0.35
17 20 25
LIQUID
PETROLEUM GAS
(Butane) G30
rapid
semi-rapid
87
67
3.00
1.65
218 g/h
120 g/h
0.60
0.35
20 28-30 35
LIQUID
PETROLEUM GAS
(Propane) G31
rapid
semi-rapid
87
67
3.00
1.65
214 g/h
118 g/h
0.60
0.35
25 37 45
Type of gas
used
Configuration model Rated thermal
flow rate kW
Total rated
consumption
Air necessary (m
3
) for the
combustion of 1 m
3
of gas
G20 20 mbar 2 burners 4.65 443 l/h 9.52
G30 28-30 mbar 2 burners 4.65 338 g/h 30.94
G31 37 mbar 2 burners 4.65 332 g/h 23.8