Instruction for Use

PRODUCT DESCRIPTION SHEET
EN
5019 300 02756
To get full satisfaction from the hob, please read these instructions carefully and keep them for future consultation.
FR
USE OF THE GAS BURNERS
To ignite one of the burners, turn the relative knob anti-clockwise to the maximum flame setting.
Press the knob against the control panel to ignite the burner.
After the burner has ignited, keep the knob pressed for about 5 seconds to allow the thermocouple to warm up.
This burner safety device shuts off the gas supply to the burner if the flame goes out accidentally (because of sudden
draught, an interruption in the gas delivery, boiling over of liquids, etc.).
The device must not be pressed for more than 15 sec. If, after that time has elapsed, the burner does not
remain lit, wait at least one minute before trying to light it again.
- The burner might go out when the knob is released. This means that the thermocouple has not warmed up enough.
In this case, repeat the operations described above.
PRACTICAL ADVICE FOR USING THE GAS BURNERS
For optimum burner performance, observe the following
rules:
- Use pots and pans that fit the burners (see table on the
right).
- Only use flat-bottomed pots and pans.
- Use the correct amount of water for cooking foods and
keep the pot covered.
PRACTICAL ADVICE FOR USING THE INDUCTION
COOKING ZONE
- Use only pots with the symbol “INDUCTION SYSTEM”
- For existing pots and pans, use a magnet to check
suitability: pots are unsuitable if they cannot be
magnetically detected
- Use pots and pans that fit the burners (see table on the
right)
4
57
3 2
6
1
8
9
1. Removable panstand grids
2. 4-crown burner
3. Semi-rapid burner
4. Auxiliary burner
5. 4-crown burner control knob
6. Semi-rapid burner control knob
7. Auxiliary burner control knob
8. Induction zone control panel
9. Induction cooking zone
SYMBOLS
tap closed
Maximum flame
Minimum flame
Induction on/off
Induction key lock
Timer
Burner Pot Ø
Auxiliary 8 to 14 cm
Semi-rapid from 16 to 22 cm
4-crown from 24 to 26 cm
Induction zone Pot Ø
Ø 24 cm from 14 to 24 cm
DIMENSIONS AND DISTANCES TO BE MAINTAINED (mm)
NOTE: If the distance “A” between the wall cabinets is between 600 mm and 730 mm, the height “B” must be a
minimum of 520 mm.
If the distance “A” between the wall cabinets is greater than the width of the hob, the height “B” must be
a minimum of 400 mm.
In the event a hood is fitted above the hob, please refer to the hood assembly instructions for the correct
distance.
INJECTORS TABLE CATEGORY II2E+3+
ELECTRICAL SUPPLY: 220-240 V ~ 50/60 Hz
ELECTRIC HOTPLATE POWER: 3000 W
Ty p e o f g a s u s e d Ty p e of burner Injector
marking
Rated thermal
flow rate
kW
Rated
consumption
Reduced heat
capacity kW
Gas pressure mbar
BE FR min. rat. max.
NATURAL GAS
(Methane) G20
4-crown
semi-rapid
auxiliary
139
95
78
3.50
1.65
1.00
333 l/h
157 l/h
95 l/h
2.20
0.45
0.35
2.20
0.35
0.30
17 20 25
NATURAL GAS
(Methane) G25
4-crown
semi-rapid
auxiliary
139
95
78
3.50
1.65
1.00
388 l/h
183 l/h
111 l/h
2.20
0.35
0.30
20 25 30
LIQUEFIED
PETROLEUM GAS
(Butane) G30
4-crown
semi-rapid
auxiliary
90
67
50
3.20
1.65
1.00
233 g/h
120 g/h
73 g/h
1.90
0.35
0.30
20 28-30 35
LIQUEFIED
PETROLEUM GAS
(Propane) G31
4-crown
semi-rapid
auxiliary
90
67
50
3.20
1.65
1.00
229 g/h
118 g/h
71 g/h
1.90
0.35
0.30
25 37 45
Type of gas used Model configuration Rated thermal flow rate
kW
Total rated consumption Air necessary (m
3
) for the
combustion of 1 m
3
of gas
G20 20 mbar 3 burners 6.15 585 l/h 9.52
G25 25 mbar 3 burners 6.15 682 l/h 8.187
G30 28-30 mbar 3 burners 5.85 426 g/h 30.94
G31 37 mbar 3 burners 5.85 418 g/h 23.80