Instruction for Use

AKT 603 PRODUCT DESCRIPTION SHEET Destinations
GB
5019 319 01112
To get full satisfaction from the hob, please read these instructions carefully and keep them for future consultation.
GBSLHRROBGHUSKCZPL
LIGHTING THE BURNERS
To ignite one of the burners, turn the relative knob anti-clockwise to the maximum flame setting .
Press the knob against the control panel to ignite the burner.
Release the knob.
- If the flame goes out, repeat the operations described above.
- Should the flame accidentally go out, close the corresponding control knob and wait for at least 1 minute
before igniting the burner again.
PRATICAL ADVICE FOR USING THE BURNERS
For better burner performance, please stick to the following rules:
- Use pots and pans that fit the burners (see table on the
right).
- Only use flat-bottomed pots and pans.
- Use the correct amount of water for cooking foods and
keep the pot covered.
1. Removable panstand grids
2. Auxiliary burner
3. Semi-rapid burner
4. Semi-rapid burner
5. Ultra-rapid burner
6. Auxiliary burner control knob
7. Semi-rapid burner control knob
8. Semi-rapid burner control knob
9. Ultra-rapid burner control knob
SYMBOLS
Tap closed
Maximum flame
Minimum flame
Burner Pot Ø
ultra-rapid from 24 to 26 cm
semi-rapid from 16 to 22 cm
auxiliary from 8 to 14 cm
DIMENSIONS AND DISTANCES TO BE MAINTAINED (mm)
NOTE: In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct
distance.
INJECTOR TABLE CATEGORY II2E+3+
ELECTRIC SUPPLY: 230 V ~ 50 Hz
Type of gas used Type of
burner
Injector
marking
Rated
thermal flow
rate kW
Rated
consumption
Reduced heat
capacity kW
Gas pressure (mbar)
min. rat. max.
NATURAL GAS
(Methane) G20
ultra-rapid
semi-rapid
auxiliary
136
95
78
3.50
1.65
1.00
333 l/h
157 l/h
95 l/h
0.80
0.45
0.30
17 20 25
LIQUID
PETROLEUM GAS
(Butane) G30
ultra-rapid
semi-rapid
auxiliary
94
67
50
3.50
1.65
1.00
254 g/h
120 g/h
73 g/h
0.60
0.35
0.30
20 28-30 35
LIQUID
PETROLEUM GAS
(Propane) G31
ultra-rapid
semi-rapid
auxiliary
94
67
50
3.50
1.65
1.00
250 g/h
118 g/h
71 g/h
0.60
0.35
0.30
25 37 45
Type of gas
used
Configuration
model
Rated thermal
flow rate kW
Total rated
consumption
Air necessary (m
3
) for the
combustion of 1 m
3
of gas
G20 20 mbar 4 burners 7.80 742 l/h 9.52
G30 28-30 mbar 4 burners 7.80 567 g/h 30.94
G31 37 mbar 4 burners 7.80 557 g/h 23.80