Instruction for Use

This burner safety device shuts off the gas supply to the burner if the ame goes out accidentally (because of sudden draught, an interruption in the gas
delivery, boiling over of liquids, etc.).
The knob must not be pressed for more than 15 sec. If, after that time has elapsed, the burner does not remain lit, wait at least one minute before
trying to light it again.
NOTE: should particular local conditions of the delivered gas make the ignition of burner difcult, it is advisable to repeat the operation with
the knob turned to small ame setting.
The burner might go out when the knob is released. This means that the safety device has not warmed up enough. In this case, repeat the operations
described above.
DIMENSIONS AND DISTANCES TO BE MANTAINED (mm)
NOTE: if the distance “A” between the wall cabinets is between 600 mm
and 730 mm, the height “B” must be a minimum of 530 mm.
If the distance “A” between the wall cabinets is greater than the width of
the cooktop, the height “B” must be a minimum of 400 mm.
In case of installation of a hood above the cooktop, please refer to the
hood instructions for the correct distance.