Instruction for Use

CLEANING THE HOB PARTS (Appendix A) – See drawing below for parts removal guides.
To reinstall the parts (grids, caps, rings and burners) reverse depicted operation.
INJECTORS TABLE CATEGORY II2H3+
Type of
gas used
Type of
burner
Injector
marking
Primary Air
adjusting
(X)
(mm)
Rated
thermal
flow rate
kW
Rated
consumption
Reduced
heat
capacity
kW
Gas pressure
mbar
min. rat.
max.
NATURAL GAS
(Methane) G20
Ultra-Rapid 147 4.20 400 l/h 0.85
17 20 25
Rapid 125 3.00 286 l/h 0.85
Semi-Rapid BR 99 15 1.90 181 l/h 0.45
Semi-Rapid FL 86 1.40 133 l/h 0.45
Auxiliary 74 1.00 95 l/h 0.30
LIQUEFIED
PETROLEUM GAS
(Butane) G30
Ultra-Rapid 101 4.20 305 g/h 0.85
20 28-30 35
Rapid 84 3.00 218 g/h 0.85
Semi-Rapid BR 71 15 1.90 138 g/h 0.50
Semi-Rapid FL 58 1.40 102 g/h 0.50
Auxiliary 50 1.00 73 g/h 0.30
LIQUEFIED
PETROLEUM GAS
(Propane) G31
Ultra-Rapid 101 4.20 300 g/h 0.85
25 37 45
Rapid 84 3.00 214 g/h 0.85
Semi-Rapid BR 71 15 1.90 136 g/h 0.50
Semi-Rapid FL 58 1.40 100 g/h 0.50
Auxiliary 50 1.00 71 g/h 0.30
Type of gas used Model
configuration
Rated thermal
flow rate (kW)
Total rated
consumption
Air required (m
3
) for
burning 1 m
3
of gas
G20 20 mbar 5 burners 11.50 1095 l/h 9.52
G30 28-30 mbar 5 burners 11.50 836 g/h 30.94
G31 37 mbar 5 burners 11.50 821 g/h 23.80
ELECTRIC SUPPLY: 220-240 V ~ 50/60 Hz