Operation Manual

43
WIRING DIAGRAM
Make sure that the colour of wires of the outdoor unit and the terminal number are the same as those of
the indoor unit.
Note: For 9k, 12k models, the power supply are connected from indoor unit, with a plug.
1
2
3
N
L
4
1
2
3
4
Power connecting cord
Power supply
Outdoor unit
Te r m i n a l
Indoor unit
Te r m i n a l
Brown
Blue
Yellow/Green
Black
CAUTION:
1. Use an individual power circuit specifically for the air conditioner. As for the wiring method, refer to the
circuit diagram on the inside of the access door .
2. Check that the cable thickness conforms to the power source specification.
3. Check the wires and make sure that they are all tightly fastened after cable connection.
4. Be sure to install an earth leakage circuit breaker in a wet or moist area.
Cable Specifications
Capacity
(Btu/h)
Power cord Power connecting cord
Main
power
supply
(Note)
Ty p e
Normal cross -
sectional area
Ty p e
Normal cross -
sectional area
9K,12K H05VV-F 1.5mm² X3 H07RN-F 1.5mm²X4 To indoor
Brown
Blue
Yellow/Green
Black