GB Design Series ‐ Traditional Series 800 ‐ Traditional Series 700 REFRIGERATING UNITS INSTRUCTIONS FOR THE INSTALLATION AND USE OF REFRIGERATING UNITS ASE 500 ASE 501 ASE 502 ASE 503 ASE 504 ASE 505 ASE 506 ASE 507 ASE 508 ASE 509 ASE 510 ASE 511 ASE 512 ASE 513 ASE 514 ASE 515 ASE 516 ASE 517 ASE 518 ASE 519 ASE 520 ASE 521 ASE 522 ASE 523 ASE 524 ASE 525 ASE 526 ASE 527 ASE 528 ASE 529 ASE 530 ASE 531 ASE 532 ASE 533 ASE 534 ASE 535 ASE 536 ASE 537 ASE 538 ASE 539 ASE 540 ASE 541 ASE 542 ASE 543 ASE
INDEX 1.GENERAL WARNINGS pg.3 2.SPECIAL WARNINGS FOR POSITIONING AND CONNECTING THE APPLIANCE pg.4 3.POSITIONING pg.4 4.REFRIGERATED DISPLAY COUNTER pg.4 5.LAWS AND DIRECTIVES pg.5 6.ELECTRICAL AND EQUIPOTENTIAL CONNECTION pg.5 7.CONDENSATION WATER DRAWING pg.5 8.GENERAL INSTRUCTIONS FOR USE pg.6 9.CLEANING AND CARE OF APPLIANCE pg.6 10.CONTROL PANELS pg.7 11.USE AND OPERATION pg.
1) GENERAL WARNINGS Only qualified installed and personnel authorised by the manufacturer can carry out installation, start-up and maintenance operations on the equipment. Read the instructions contained in this manual very carefully, as they are very important for safety in case of installation, use and maintenance. 1.The appliance must be used only for its intended purpose, i.e. for holding previously chilled food or drinks; the appliance is not designed for any other use that is therefore prohibited. 2.
2) SPECIAL WARNINGS FOR POSITIONING AND CONNECTION According to prescriptions, a unipolar switch with contacts open at least 3 mm per pole must be installed between the equipment and the power supply network. In addition, the ground wire must not be interrupted. Stand the refrigerated unit so that the airing grids of the condensing units are not obstructed by walls, furniture or other equipment. Keep at a minimum distance of 200 mm. 3) POSITIONING Remove the protective film from the appliance.
) LAWS AND DIRECTIVES When connecting the appliance, comply with the following prescriptions: 1.Current building regulations and fire safety prescriptions 2.Current safety standards 3.Installation rules, CEI STANDARDS. 6) ELECTRICAL AND EQUIPOTENTIAL CONNECTION The power cord can be reached by unscrewing and opening the vent on the right (serving side). The on/off switch before the appliance must be near it and easy to reach. The appliance is normally supplied with the cord already fitted.
8) GENERAL INSTRUCTIONS FOR USE Read the instructions contained in this paragraph very carefully; they contain general instructions concerning safety, operation and maintenance of the appliance. The appliance has already been submitted to a strict control by qualified personnel at the end of the process. Any repairs that may become necessary in time should be carried out only by qualified personnel.
10) CONTROL PANEL VERSION DESIGN SERIES: : LEGEND: A) MAIN ON/OFF SWITCH B) LIGHT SWITCH C) DISPLAY COUNTER THERMOSTAT D) TOP THERMOSTAT E) CHAMBER THERMOSTAT VERSION TRADITIONAL: LEGEND: A) MAIN ON/OFF SWITCH B) LIGHT SWITCH C) DISPLAY COUNTER THERMOSTAT D) TOP THERMOSTAT The temperature inside the chamber, display counter or on the top appear on the display.
11) USE AND OPERATION 1.Switch the appliance on (ON/OFF switch). 2.Set the desired temperatures. The appliance takes one hour to reach operating temperature. 3.To ensure that the food and/or drinks are always kept at the right temperature, it is advisable to set the thermostats at a temperature of respectively -0/+2°C (Thermostat Top/tank) 0/+6°C (Thermostat cell) und +5/10°C (Thermostat display counter) 4.