Installation Instruction

20
ELECTRIC DRYER ELECTRICAL CONNECTIONSELECTRIC DRYER ELECTRICAL CONNECTIONS
F
F
WARNING
Fire Hazard
Use 10 gauge copper wire.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal (silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
Direct Wire Connection
Remove Terminal Block Cover
3. Connect remaining wires under outer terminal block screws
(F). Tighten screws. Finally, reinstall terminal block cover to
dryer rear panel. Secure cover with hold-down screw. Now
go to “Venting Requirements.”
Connecting 3-Wire Connection: Power Supply Cord (cont.)
2. Connect neutral wire (white or center wire) (D) of power
supply cord under center terminal block screw (A). Tighten
screw.
A
D
Remove hold-down screw and terminal block cover.
Direct Wire Strain Relief
1. Insert strain relief.
A
B
C
Unscrew the removable conduit connector (A) and any
screws from a 3/4" (19 mm) UL listed strain relief). Put the
threaded section of the strain relief (C) through the hole below
the terminal block opening (B). Reaching inside the terminal
block opening, screw the removable conduit connector (A)
onto the strain relief threads.
Put direct wire cable through the strain relief. The strain
relief should have a tight t with the dryer cabinet and be in
a horizontal position. Tighten strain relief screw against the
direct wire cable.
2. Insert conduit into strain relief and tighten clamp.