Installation Instruction

29
Code Explanation
L. 00 PRICE SUPPRESSION OPTION
This option is either Selected ‘ON’ or Not Selected
‘OFF’. This option causes the customer display to
show ‘AVAILABLE’ or ‘ADD’ rather than the amount
of money to add. (Used mainly in debit installations.)
L. 00 Not Selected ‘OFF’.
L. PS Selected ‘ON’. Press the COLORS/DELICATES button
once for this selection.
Press the PERM PRESS button once to advance
to next code.
n. CE CLEAR ESCROW OPTION
This option is either Selected “ON” or Not Selected
“OFF.” When selected, money held in escrow for
30minutes without further escrow or cycle activity will
be cleared.
n. 00 Not Selected “OFF.”
n. CE Selected “ON.”
Press the COLORS/DELICATES button once
to change this selection.
Press the PERM PRESS button once to advance
to next code.
U. 00 PENNY INCREMENT OFFSET
U. 00 This represents the penny increment price offset
used in Generation 2 (Enhanced Debit) 9160 models.
Choose from 0–4 pennies by pressing the COTTON/
WHITES button.
Press the PERM PRESS button once to advance
to next code.
If cycle counter (9 0C) is selected, the following is true:
1 00 Cycles in HUNDREDS 1 02 = 200
2 00 Cycles in ONES 2 25 = 25
TOTAL CYCLES = 225
This is “VIEW ONLY” and cannot be cleared.
Press the PERM PRESS button once to advance
to next code.
If money counter (1.0C or 1.C0) is selected, the following
is true:
3 00 Dollars in HUNDREDS 3 01 = $100.00
4 00 Dollars in ONES 4 68 = $ 68.00
5 00 Number of CENTS 5 75 = $ 00.75
TOTAL = $168.75
END of SET-UP PROCEDURES
TO EXIT FROM SET-UP MODE
1. Close the service access door.
2. Disconnect dryer from power before reinstalling the AA1
connector, if it was removed.
3. Remove the manual set-up card.
4. Wait two minutes without activating any dryer inputs.
5. Disconnect and then reconnect power.
ELECTRONIC CONTROL SETUP INSTRUCTIONSELECTRONIC CONTROL SETUP INSTRUCTIONS
Diagnostic Codes
If the set-up mode is entered and one of the following has
previously occurred, the appropriate diagnostic code will be
in the display.
Dryer Display Explanation
d 5 Blocked coin 1 or coin drop UI control
circuit failure (coin recognition and
customer display disabled while
blockage persists).
d 9 Voltage detected below 90 VAC for
8 seconds.
d 13 Blocked coin 2 or coin drop UI control
circuit failure (coin recognition and
customer display disabled while
blockage persists).
d 16 Not receiving communications from
installed debit card reader in Enhanced
(Generation 2) Debit mode.
F 01 Dryer motor control circuit error
(cycles and price display disabled until
diagnostic code is manually cleared).
The control doesn’t know if the motor
relay is bad (stuck on), the motor relay
drive circuit is bad (shorted), causing
the motor relay to stay on, or the
motor relay feedback circuit is bad.
F 22 Exhaust thermistor open, temperature
drops below 18°F (>50 kΩ) for
1minute in Run mode, or immediately
in Factory Diagnostic Mode.
F 23 Exhaust thermistor shorted,
temperature above 250°F (<500 Ω) for
1 minute in Run mode, or immediately
in Factory Diagnostic Mode.
F 70 UI is not receiving communications
from CCU (cycles and price display
disabled while error persists or is
manually cleared).
F 71 CCU is not receiving communications
from UI (cycles and price display
disabled while error persists
or is manually cleared).
F 73 UI Microprocessor is not able to read
or verify EEPROM (cycles and price
display disabled until diagnostic code
is manually cleared).
F 74 UI EEPROM memory is a CRC failure
(cycles and price display disabled until
diagnostic code is manually cleared).