INSTALLATION INSTRUCTIONS COMMERCIAL STACKEDDRYER Gas (120-Volt,60-Hz)or Electric (120/240-Volt,60-Hz) Table of Contents ........................................................ 2 Actual unit may or may not contain doors with windows depending on model W10135152A www.whirlpool.
TABLEOF CONTENTS DRYER SAFETY ............................................................................ 2 INSTALLATION REQUIREMENTS 4 .............................................. Location Requirements .............................................................. Tools and Parts .......................................................................... 4 5 Electrical Requirements ............................................................ 6 Gas Supply Requirements 7 ........................
WARNING: For your safety, the information in this manual must be followed to minimize the risk of fire or e×plosion, or to prevent property damage, personal injury, or death. - Do not store or use gasoline or any other appliance. or other flammable - WHAT TO DO iF YOU SMELL GAS: vapors and liquids in the vicinity of this = Do not try to light any appliance. = Do not touch any electrical switch; do not use any phone in your building. • Clear the room, building, or area of all occupants.
INSTALLATIONREQUIREMENTS Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. Tools needed • 8" or 10" pipe wrench • • 8" or 10" adjustable wrench Flat-blade screwdriver • Phillips screwdriver • Adjustable wrench that opens to 1" (2.5 cm) or hex-head socket wrench Keep flammable materials and vapors, such as gasoline, away from dryer. • Level Do not install in a garage.
Minimum Installation Clearances Recessed Closet Product Dimensions Back 0 in Sides 0 in Top 6 in Front -- (0 cm) 0 in (0 cm) (0 cm) 0 in (0 cm) (15.2 cm) 0 in (0 cm) 7 in (17.8 cm) top exhaust -_. _ 011(0 cm) -- 13-1/2" (34.3 cm) t Back View IUL_r 0" 1 O (15.2 cm) (0 cm) O 6" EJ 41" (104.1 cm) 3 bottom... exhaust closet door 0 0" (0 cm)-_,- Closet side view x _- /I --_-|1-_-0" (0 cm) vI Recessed front view 27" (68.
IMPORTANT: The dryer must be electrically grounded in accordance with local codes and ordinances or, in the absence of local codes, with the National Electrical Oode, ANSI/NFPA 70, latest edition. The National Electric Oode requires a 4-wire supply connection for homes built aRer 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations. Electrical Shock Hazard Plug into a grounded 3 prong outlet.
Gas Supply Line Recommended method • Provide a gas supply line of 1/2"rigid (IPS) pipe to the dryer location. Pipe joint compounds that resist the action of LP gas must be used. Do not use TEFLON _t tape. With LP gas, piping or tubing size can be 1/2"minimum. Usually, LP gas suppliers determine the size and materials used in the system. Alternate method • Explosion Hazard Use a new CSA International approved gas supply line. Install a shut-off valve.
Plan installation to use the fewest number of elbows and turns. Gas Supply Pressure Testing A 1/8"NPT minimum plugged tapping, accessible for gauge testing, must be installed immediately upstream of the gas supply connection to the dryer. A The dryer must be disconnected from the gas supply piping system during any pressure testing of the system at test pressures in excess of 1/2psig. ExhaustAir Flow A. Better B. Good Allow as much room as possible when using elbows or making turns.
If an exhaust hood cannot be used: Multiple Dryer Venting • A main vent can be used for venting a group of dryers. Main vent should be sized to remove 200 CFM of air per dryer. Large-capacity lint screens of proper design may be used in the main vent if checked and cleaned frequently. The room where the dryers are located should have make-up air equal to or greater than the CFM of all the dryers in the room. • Back-draft Damper Kits, Part No.
INSTALLATION INSTRUCTIONS - GASDRYER The collar houses the accumulator button. timer with actuating arm and 9. Secure the coin slide mechanism from inside the control panel using the ¾e" bolt and washer included with the slide mechanism. The factory-installed timer is set to provide 45 minutes (4 pins) of drying time when activated by the coin slide. Timer cams for 30-minute (6 pins) and 60-minute (3 pins) drying times are included in the parts bag.
2. ......... _ __ _, 1. With dryer in final position place level on top of the dryer, first side to side; then front to back. If the dryer is not level, adjust the legs of the dryer up or down until the dryer is level. Plug into a grounded 3 prong outlet. 3. Check dryer operation (some accumulated time may be on the timer due to factory testing). Insert coins in slide and press slide in slowly. (Operating time will accumulate per number of coins and type of timing cam used.) Push START/RESTART button.
2. Power Supply Cord Remove hold-down screw and terminal block cover. Method This dryer is manufactured with the neutral ground wire connected to he neutral (center) of the wiring harness at the terminal block. If local codes do not permit this type of connection, use "Four-wire connection", instructions. Use a ULlisted power supply cord rated 240 volt min., 30-amp and marked for use with a clothes dryer. A. External ground conductor screw B. Tab C. Terminal block cover D. Hold-down screw 3.
Use this method where local codes permit connecting Power Supply Cord, Three-wire electrical connection: A _ ........... f 5. Loosen or remove the center terminal block screw. ,,_ F ...... neutral groundthewire to neutral wire:or center) 6. Connect neutral wire (white of the power supply cord to the center, s j' _"'' / I silver-colored terminal block.terminal Tighten screw screw.of the I E -,,,, Connect the other wires to outer terminal block screws. Tighten screws. 8. 9. A .............
DirectWire 1. 2. Method Disconnect power. Remove hold-down screw and terminal block cover. A. External ground conductor screw B. Tab Fire Hazard C. Terminal block cover D. Hold-down screw Use 10 gauge solid copper wire. Use a UL listed strain relief. 3= Disconnect power before making electrical connections. Connect neutral wire (white or center wire) to center terminal (silver). Install 3/4"conduit connector into the hole below the terminal block opening.
DirectWire, Three-wireelectricalconnection: Use this method where local codes permit connecting neutral ground wire to neutral wire: 5. Loosen or remove the center terminal block screw. 6. Three wire with ground wire: green or bare wire cut short. Wire is not used. Dryer is grounded through neutral conductor. A 1" '4 to '_X disconnect X box Place the hooked end of the neutral wire (white or center) of the direct wire cable under the center screw of the terminal block (hook facing right).
CHANGINGTOA 30-OR 60.MINUTETIMINGCAM 5. Insert a narrow, flat-blade screwdriver under the timing cam near the clock shaft. Gently lift cam straight up and off shaft making sure that the V-shaped notch clears the ratchet tooth. Electrical Shock Hazard Disconnect power before making cam changes. Failure to follow these instructions or electrical shock.