INSTALLATION INSTRUCTIONS Commercial Stacked Dryer Gas (120 V, 60 Hz) or Electric (120/240 V, 60 Hz) TABLE OF CONTENTS DRYER SAFETY.............................................................................2 TOOLS & PARTS............................................................................5 DIMENSIONS/CLEARANCES....................................................6 LOCATION REQUIREMENTS.....................................................7 GAS DRYER ELECTRICAL REQUIREMENTS........................
DRYER SAFETY ■■ It is recommended that the owner post, in a prominent location, instructions for the customer’s use in the event the customer smells gas. This information should be obtained from your gas supplier. ■■ Post the following warning in a prominent location.
DRYER SAFETY WARNING: FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death or property damage. – Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. – WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Clear the room, building, or area of all occupants.
DRYER SAFETY IMPORTANT SAFETY INSTRUCTIONS WARNING: To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic precautions, including the following: ■■ Read all instructions before using the dryer. ■■ This dryer is intended only for drying clothes and textiles that have been washed in water. Do not use for any other purpose. ■■ WARNING: If you smell gas, do not use the dryer or any electrical equipment nearby. Warn other people to clear the area.
TOOLS & PARTS Tools Needed: 8" (200 mm) or 10" (250 mm) Pipe wrench TORX® T20®† security screwdriver or bit 8" (200 mm) or 10" (250 mm) Adjustable wrench that opens to 1" (25 mm) Flat-blade screwdriver 1" (25 mm) Hex-head socket wrench 5/16" (8 mm) Socket wrench Phillips screwdriver Pliers (that open to 19/16" [39 mm]) Level Utility knife 1/4" (6 mm) Nut driver 27" (686 mm) Wood block Caulk gun and caulk Vent clamps (for installing new exhaust vent) Flashlight (option
DIMENSIONS/CLEARANCES Dimension: Front View 27" (686 mm) Side View 5" (127 mm) Back View 29" (737 mm) 101/2" (267 mm) 763/ 4" (1950 mm) PD Models (1950 mm) Coin Models 741/ 4" (1886 mm) Non-Coin / Card-Ready Models Coin Models Coin Models Non-Coin / Card-Ready Models Non-Coin / Card-Ready Models Minimum Clearance: Front View, Recessed Opening Side View, Recessed In Closet 0" (0 mm) 12" (300 mm) 2 ¼" (57 mm) Closet Door Minimum Acceptable Vent Sizes 3" (76 mm) 76mm) 3" 3"/3" (76 mm) 1" (25 m
LOCATION REQUIREMENTS WARNING When installing a gas dryer: IMPORTANT: Observe all governing codes and ordinances. ■■ Check code requirements: Some codes limit or do not permit installation of clothes dryers in garages, closets, or sleeping quarters. Contact your local building inspector. ■■ Make sure that lower edges of the cabinet, plus the back and Explosion Hazard Keep flammable materials and vapors, such as gasoline, away from dryer.
GAS DRYER ELECTRICAL REQUIREMENTS Gas Dryer Grounding IMPORTANT: The dryer must be electrically grounded in accordance with local codes and ordinances or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, latest edition, or Canadian Electrical Code, CSA C22.1. If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate.
GAS REQUIREMENTS Gas Supply WARNING Explosion Hazard Use a new CSA International approved gas supply line. Install a shut-off valve. Securely tighten all gas connections. If connected to propane, have a qualified person make sure gas pressure does not exceed 13" (33 cm) water column. Examples of a qualified person include: licensed heating personnel, authorized gas company personnel, and authorized service personnel. Failure to do so can result in death, explosion, or fire.
ELECTRIC DRYER ELECTRICAL REQUIREMENTS (U.S.A. ONLY) It is your responsibility: ■■ To contact a qualified electrical installer. ■■ To be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70-latest edition and all local codes and ordinances. ■■ The National Electrical Code requires a 4-wire power supply connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations.
ELECTRIC DRYER ELECTRICAL REQUIREMENTS (U.S.A. ONLY) Electric Dryer Power Supply Cord WARNING Fire Hazard Use a new UL listed 30 amp power supply cord. Use a UL listed strain relief. Disconnect power before making electrical connections. Connect neutral wire (white or center wire) to center terminal. Ground wire (green or bare wire) must be connected to green ground connector. Connect remaining 2 supply wires to remaining 2 terminals. Securely tighten all electrical connections.
DRYER VENTING REQUIREMENTS WARNING Elbows: ■■ 45° elbows provide better airflow than 90° elbows. Good Better Fire Hazard Use a heavy metal vent. Do not use a plastic vent. Do not use a metal foil vent. Failure to follow these instructions can result in death or fire. WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS. IMPORTANT: Observe all governing codes and ordinances.
DRYER VENTING REQUIREMENTS Vent Hoods 4" (102 mm) Diameter Exhaust Hoods Box hood Louvered hood Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exaust (such as flowers, rocks, bushes, or snow). Angled hood 12" min. (305 mm) Vent System Length Maximum Vent Length/Vent Connection Maximum length of vent system depends upon the type of vent used, number of elbows, and type of exhaust hood. 3. Tighten hose clamp with Phillips screwdriver.
DRYER VENTING REQUIREMENTS If an Exhaust Hood Cannot be Used Multiple Dryer Venting The outside end of main vent should have a sweep elbow directed downward. A main vent can be used for venting a group of dryers. The main vent should be sized to remove 5663 l/min. (200 CFM) of air per dryer. Large-capacity lint screens of proper design may be used in main vent if checked and cleaned frequently.
INSTALLING LEVELING LEGS 1. Prepare dryer for leveling legs NOTE: Slide dryer onto cardboard or hardboard before moving to avoid damaging floor covering. Using two or more people, move dryer to desired installation location. Take tape off front corners of dryer. Open dryer and remove the literature and parts packages. Wipe drum interior with damp cloth to remove any dust. Take two cardboard corners from the dryer carton and place them on the floor in back of the dryer.
LEVELING Leveling your dryer properly reduces excess noise and vibration. 2. Grip dryer from top and rock back and forth, making sure all four feet are firmly on floor. Repeat, rocking dryer from side to side. If dryer rocks, adjust leveling feet. 1. Remove cardboard from beneath dryer. Place a level on top edges of dryer, checking each side and front. If not level, tip dryer and adjust feet up or down, repeating as necessary. Not Level LEVEL Not Level 3.
GAS SUPPLY CONNECTION Type of Gas This dryer is equipped for use with natural gas. It is certified by UL for use with propane gas with appropriate conversion. No attempt shall be made to convert dryer from gas specified on serial/rating plate for use with a different gas without consulting the serving gas supplier. Conversion must be done by a qualified service technician. Gas conversion kit part numbers are listed on gas valve burner base.
ELECTRIC DRYER ELECTRICAL CONNECTIONS (FOR U.S.A. ONLY) Power Supply Cord Connection WARNING Remove Terminal Block Cover C C B D B Fire Hazard Use a new UL listed 30 amp power supply cord. Use a UL listed strain relief. Disconnect power before making electrical connections. Connect neutral wire (white or center wire) to center terminal. Ground wire (green or bare wire) must be connected to green ground connector. Connect remaining 2 supply wires to remaining 2 terminals.
ELECTRIC DRYER ELECTRICAL CONNECTIONS Power Supply Cord Connection (cont.) 2. Insert power cord into strain relief. Put power supply cord through the strain relief. Be sure that the wire insulation on the power supply cord is inside the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Do not further tighten strain relief screws at this point.
ELECTRIC DRYER ELECTRICAL CONNECTIONS Connecting 3-Wire Connection: Power Supply Cord (cont.) 2. Connect white neutral wire (white or center) (D) to center terminal block. Tighten screw. 3. Connect remaining wires with outer terminal block screws (F). Tighten screws. Finally, re-install terminal block cover and tighten hold-down screw. Go to “Complete Installation” section. D F F ELECTRIC DRYER ELECTRICAL CONNECTIONS (FOR U.S.A.
Remove Terminal Block Cover 2. Insert conduit into strain relief and tighten clamp. C C B D Put direct wire cable through the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Tighten strain relief screw against the direct wire cable. B E A E D A Before you start, disconnect power. Remove hold-down screw (D) and terminal block cover (A). A. Terminal block cover B. External ground conductor screw C. Center terminal block screw D.
ELECTRIC DRYER ELECTRICAL CONNECTIONS Connecting 4-Wire Connection: Direct Wire IMPORTANT: A 4-wire connection is required where local codes do not permit the use of 3-wire connections. Direct wire cable must have 5 ft. (1.52 m) of extra length so dryer can be moved if needed. Strip 5" (127 mm) of outer covering from end of cable, leaving bare ground wire at 5" (127 mm). Cut 11⁄2" (38 mm) from three remaining wires. Strip insulation back 1" (25 mm). Shape ends of wires into a hook shape.
ELECTRIC DRYER ELECTRICAL CONNECTIONS Connecting 3-Wire Connection: Direct Wire Use where local codes permit connecting cabinet-ground conductor to neutral wire. Direct wire cable must have 5 ft. (1.52 m) of extra length so dryer can be moved if needed. Strip 31⁄2" (89 mm) of outer covering from end of cable. Strip insulation back 1" (25 mm). If using 3-wire cable with ground wire, cut bare wire even with outer covering. Shape ends of wires into a hook shape. B D Connecting Neutral Wire 1.
COMPLETE INSTALLATION 1. Check the electrical requirements. Be sure that you have the correct electrical supply and the recommended grounding method. See “Electrical Requirements.” 2. Check that all parts are now installed. If there is an extra part, go back through the steps. 3. Check that you have all of your tools. 4. Dispose of/recycle all packaging materials. WARNING Electrical Shock Hazard Plug into a grounded 3 or 4 prong outlet. Do not remove ground prong. Do not use an adapter.
REVERSING DRYER DOOR SWING (OPTIONAL) You can change your door swing from a right-side opening to left-side opening, if desired. Remove the Door Assembly 7. Be certain to keep cardboard spacer centered between doors. Reattach outer door panel to inner door panel so handle is on the side where hinges were just removed. 1. Place a towel or soft cloth on top of work space to avoid scratching of the surface. 2. Open dryer door. Remove button screws from cabinet side of hinges.
MAINTENANCE INSTRUCTIONS ■■ Clean lint screen before and after each cycle. ■■ Removing accumulated lint: From inside the dryer cabinet: Lint should be removed every two years or more often, depending on dryer usage. Cleaning should be done by a qualified person. From the exhaust vent: Lint should be removed every two years, or more often, depending on dryer usage. ■■ Keep area around dryer clear and free from combustible If dryer does not operate, check the following: ■■ Electrical supply is connected.
ELECTRONIC CONTROL SETUP INSTRUCTIONS IMPORTANT Electrostatic Discharge (ESD) Sensitive Electronics ESD problems are present everywhere. ESD may damage or weaken the electronic control assembly. The new control assembly may appear to work well after repair is finished, but failure may occur at a later date due to ESD stress. ■■ Use an anti-static wrist strap. Connect wrist strap to green ground connection point or unpainted metal in the appliance.
ELECTRONIC CONTROL SETUP INSTRUCTIONS Control Setup Procedures Code Explanation IMPORTANT: Read all instructions before operating. 606 REGULAR CYCLE PRICE The fabric setting buttons along with the digital display are used to set up the dryer controls. The display can contain four numbers and/or letters and a decimal point. These are used to indicate the setup codes and related code values available for use in programming the appliance.
ELECTRONIC CONTROL SETUP INSTRUCTIONS Code Explanation 1. 00 MONEY COUNTER OPTION This option is either NOT SELECTED “OFF” or SELECTED “ON.” 1. 00 Not Selected “OFF.” 1. 0C Selected “ON.” OPTIONS 3.XX – 9.XX TO USE IF SPECIAL PRICING IS SELECTED Code Explanation 3.06 SPECIAL CYCLE PRICE 3.06 Represents the number of quarters (coin 1) to start the dryer; may adjust from 0–39. (See VALUE OF COIN 1 b.05.
ELECTRONIC CONTROL SETUP INSTRUCTIONS Code Explanation Code Explanation 7. 00 SPECIAL PRICE START HOUR b. 05 VALUE OF COIN 1 NOTE: Uses military time or 24 hr. clock. b. 05 This represents the value of coin 1 in number of nickels: 05 = $0.25. 7. 00 This is the start hour; 0–23 hours. ■■ Select START HOUR by pressing the WHITES ■■ By pressing the WHITES AND COLORS button, AND COLORS button. there is an option of 1–199 nickels. ■■ Press the PERM. PRESS button once to ■■ Press the PERM.
ELECTRONIC CONTROL SETUP INSTRUCTIONS END of SETUP PROCEDURES Code Explanation J. Cd PAYMENT MODE (COIN/DEBIT OPTION) J. Cd Both coin and debit selected. Press the DELICATES button three consecutive times to change this selection. J. C_ Coins selected, debit disabled. Press the DELICATES button three consecutive times to change this selection. DIAGNOSTIC GUIDE Debit Card selected, coins disabled. Press the DELICATES button three consecutive times to change this selection. STACKED DRYERS J._d J.
WHIRLPOOL® COMMERCIAL LAUNDRY LIMITED WARRANTY IF YOU NEED SERVICE: Contact your authorized Whirlpool® Commercial Laundry distributor. To locate your authorized Whirlpool® Commercial Laundry distributor, call: 1-800-662-3587, or for web inquiries, visit www.whirlpoolcommerciallaundry.com.
W11255762A W11255763A-SP 07/18 / ® TM ©2018 Whirlpool. All rights reserved.