SECTION IH
GAS CONVERSION
A. GENERAL
All sealed burner ranges and cooktops are equipped with double coaxial (universal) orifices
and with a convertible gas regulator. The unit model number plate states which gas it was
adjusted for at the factory. To convert the unit to either Natural gas or LP gas will require
adjustment of the surface burner orifice hoods, adjustment of the oven orifice/air shutter and
replacement and/or adjustment of the pressure regulator converter cap.
B. REGULATOR CONVERSION
The unit regulator must be set to match the type gas supply used. If converting from natural
gas to LP gas, the regulator must be converted to regulate LP gas. If converting from LP gas
to natural gas, the regulator must be converted to regulate to natural gas.
TO CONVERT THE PRESSURE REGULATOR FROM ONE GAS TO ANOTHER, DO
EITHER (1) (2) OR (3) BELOW: YOUR _ WILL BE EQUIPPED WITH ONE OF
THE THREE REGULATOR TYPES SHOWN BELOW.
F_GURE10 FIGURE11 RGURE12
I. Remove the cap, push down and turn counter clockwise. Turn the cap over and reinstall
(figure 10). NOTE: THE GAS TYPE YOU ARE CONVERTING TO MUST BE VISIBLE
ON THE TOP OF THE INSTALLED REGULATOR CAP.
2. Remove plastic dust cover from cap nut on top of regulator. Remove cap nut from regu-
lator (plastic dust cover comes off with nut). "IMPORTANT" remove plastic dust cover
from cap nut and reinstall on opposite side of cap nut.