Specifications

4-17
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug washer or disconnect power.
2. Turn off the water supply to the washer.
3. Remove the lower front access panel (see
step 10 on page 4-11 for the procedure).
REMOVING THE DRAIN PUMP
4. Using a shallow pan to catch the water,
unscrew the filter from the drain pump,
and drain the water from the pump.
Drain Pump
5. Loosen the clamp and remove the pump-
to-tub hose from the drain pump.
6.
Loosen the clamp and remove the pump-
to-drain hose from the drain pump.
REASSEMBL
Y NOTE: When you reconnect
the hoses, align their tab(s) with the marks on
the drain pump.
Drain Pump Filter
Pump-To-Tub Hose
Pump-To-
Drain Hose
7. Using a flat-blade screwdriver, lift the
rubber pad, and slide the pump to the left
and unhook the bottom tab, then lift the
pump out of the chassis floor slots.
Tab
Tabs
Arrow
Lift Rubber Pad
Tab
Continued on the next page.