Specifications

5-4
Electrical Shock Hazard
Disconnect power before accessing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
DETERGENT DISPENSER
MOTOR & SWITCH
Refer to page 4-13 for the procedure for ac-
cessing the detergent dispenser motor.
To check the motor at the component termi-
nals, perform the following steps.
1.
Unplug washer or disconnect power.
2. Disconnect the two wire connectors from
the motor and switch terminals.
3.
Set the ohmmeter to the R X 100 scale.
4. Touch the ohmmeter test leads to the
following connector terminals (shown
above). The meter should indicate as fol-
lows:
Motor
Terminals = 1400 Ω
Switch
Terminals = 0 Ω
T
o check the motor at the CCU, perform the
following steps.
1.
Unplug washer or disconnect power.
2. Disconnect the detergent dispenser
connector DI6 (see page 4-5) from the
CCU.
3.
Set the ohmmeter to the R X 1 scale.
4. Touch the ohmmeter test leads to the fol-
lowing connector pins. The meter should
indicate as follows:
Motor Pins 1 & 3 = 1400 Ω
Switch Pins 5 & 6 = 0 Ω
Connector DI6
At CCU
1 2 3 4 5 6
Motor
Terminals
Motor Switch
Switch
Terminals