Specifications

5-5
Electrical Shock Hazard
Disconnect power before accessing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
DOOR SWITCH
3. Set the ohmmeter to the R X 1 scale.
4. To test the door lock/unlock sole-
noids, touch
the ohmmeter test leads to
the indicated pins on connector DL3. The
meter should indicate as follows:
Door Unlock Solenoid - Pins 2 & 3 = 60 Ω
Door Lock Solenoid - Pins 1 & 3 = 60 Ω
5.
Disconnect the door switch connector
DS2 (see page 4-5) from the CCU.
6. T
o test the door switch, touch the ohm-
meter test leads to pins 3 and 1 at DS2.
The meter should indicate as follows:
Door Closed = 0 Ω
Door Open = infinite
Door Lock/
Unlock
Solenoids
Door Switch
1 2 3
1 2 3
1 2 3
Door Sw.
Lock Sol.Unlock Sol.
Connector DS2
At CCU
Connector DL3
At CCU
Refer to page 4-14 for the procedure for ac-
cessing the door switch.
T
o check the door switch at the CCU, perform
the following steps.
1.
Unplug washer or disconnect power.
2. Disconnect the door lock/unlock sole-
noids connector DL3 (see page 4-5) from
the CCU.