Troubleshooting guide

22
8. Long off Cycle - Too Warm at Start A. Low ambient temperature
B. Freezer temperature control knob set too warm.
C. Freezer temperature control out of calibration
9. Short off Cycle A. High ambient and/or heavy usage
B. Freezer control knob set too cold.
C. Freezer control out of calibration.
D. Light on constantly
E. Poor door seal
10. Long or Continuous Operation A. High ambient and/or heavy usage
B. Inadequate condenser air flow
C. Freezer temperature set too cold.
D. Freezer temperature control out of calibration.
E. Freezer temperature control relay frozen closed.
F. Loss of refrigerant or restriction
11. Short Run Cycle A. Low ambient and/or light usage
B. Freezer temperature control setting too warm or control out of
calibration
12. Condensation on Cabinet Exterior A. High humidity installation (design accepts bead of water on
exterior of cabinet after 4 hours with a 0° to 2°F. (-18° to -17°C.)
freezer food temperature and 38° to 40°F. (3°C to 4°C) refrig-
erator food temperature in 84% R.H. conditions (See example
of typical sweat pattern under above conditions.
Fig. 13
)
B. Freezer control set too cold.
C. Freezer control out of calibration
D. Poor door gasket seal.
E. Insulation void.
13. Unit will not Deliver Ice Cubes A. No power to auger drive motor. Check circuitry through ice ac-
tuator switch and upper freezer breaker auger motor switch.
B. Drive Motor open
C. Run Capacitor inoperative.
D. Drive motor tripped out on overload after 90 seconds of con-
tinuous use. Allow three minutes to reset.
E. Nonelectrical malfunctions. Power off for a period of time lets
the cubes refreeze together. No use for a period of time lets the
cubes freeze together. Improperly sealing chute door (check with
flash light). Malfunction in drive train components of bucket
assembly.
14. Unit will not Deliver Water A. No power to water dispensing solenoid vase. Check circuitry
through water dispensing switch.
B. Water dispensing solenoid valve coil open
C. Water dispensing switch open
D. Water dispensing arm does not close water dispensing switch.
E. Water line or tank frozen.
F. Freezer door interlock switch is open.
15. Water Delivery Slow A. A kink in the tubing may restrict the water flow. Replace the
water line. Flow rate should be 1.7 to 3.5 liter per minute with
inlet pressure from 20 to 120 PSI (1.38 to 8.2 BAR).
16. Water Accumulating in the A Leak in the water tank or connection
Refrigerator Bottom Area
PROBLEM
POSSIBLE CAUSE
TROUBLESHOOTING