Power direct venng combines the best features of
power venng and direct venng. Power direct vented
water heaters pull combuson air from outside, but
because they use a motorized blower to exhaust
combuson by-products, they can be installed in interior
locaons using long runs of pipe. They can be concentric
vented, or two separate pipes can be used.
Power venng is used when the water heater has to be
installed in an interior locaon of the structure and a long
horizontal vent pipe must be used. The vent pipe can run
from 40 feet to as much as 120 feet, depending upon the
vent pipe diameter, Btu output of the water heater, and
the number and type of bends in the vent pipe. Power
vent water heaters have a motorized blower located at
the top of the ue that forces combuson by-products to
outside the home. Electricity is required to operate the
blower motor.
The PV and PDV models may be vented with PVC, ABS, or CPVC pipe.