Instruction for Use

10
GB
The refrigerator door has been open for more than two
minutes.
The sound alert stops when the door is closed or when the
appliance is switched off and on again.
The alarm sounds and TEMPERATURE ALARM flashes
on the display (“A1” is displayed instead of the FREEZER
temperature).
The temperature inside the freezer is too high. The freezer
will maintain a temperature of around 0°C so that the food
will not refreeze, allowing you to eat it within 24 hours or to
refreeze it after it has been cooked.
To switch off the buzzer, open and close the appliance door
or press the + and – freezer temperature adjustment buttons
once. Press these buttons a second time to display the set
value on the freezer display, switch off the TEMPERATURE
ALARM LED and restore normal operation.
The alarm sounds and temperature alarm flashes on
the display (“A2” is displayed instead of the FREEZER
temperature).
The temperature of the freezer is dangerously high: the
food inside must not be eaten. The freezer will maintain a
temperature of approximately -18°C.
To switch off the buzzer, open and close the appliance door
or press the + and – freezer temperature adjustment buttons
once. Press these buttons a second time to display the set
value on the freezer display, switch off the TEMPERATURE
ALARM LED and restore normal operation.
The refrigerator and the freezer do not cool well.
The doors do not close properly or the seals are damaged.
The doors are opened too frequently.
The temperature that has been set is too high (see Start-up and
use).
The refrigerator or the freezer have been over-filled.
The food inside the refrigerator is beginning to freeze.
The temperature that has been set is too low (see Start-up and
use).
The motor runs continuously.
The SUPER FREEZE button has been pressed (rapid
freezing): the yellow SUPER FREEZE light is on or flashing
(see Description).
The door is not closed properly or is continuously opened.
The outside ambient temperature is very high.
The appliance makes a lot of noise.
The appliance has not been installed on a level surface (see
Installation).
The appliance has been installed between cabinets that
vibrate and make noise.
The internal refrigerant makes a slight noise even when the
compressor is off. This is not a defect, it is normal.
Early ending of functions
Electrical disturbance on the network or brief interruptions of
the power supply.