Installation guide

SingUe oven
28o3/8" raax.
recessed
width
27-1/2"
recessed
height
27=3/4"
rain,
cutout
height
27=3/4"
rain,
cutout
height
1=1!2"
rain,
bottom of
cutout to
top of
cabinet
door
30" rain, --_
cabinet width
Single oven
undercounter
(without cooktop
installed above}
uu - ,
cb e dtb
28-I/2"
_-- cutout ---}_
width
Single oven
Page 1
29" max,
overati
height
OoubUe oven
2S"raa×,
recessed
depth
49=1/2"
recessed
height
29=3/4"
5I" raa×=
overall
height
r
J
1=1/2" rein.
top of cutout
to underside
of countertop
49=3/4"
rain=
cutout
height
5=I/4" bottora of
cutout to floor
1=1/2" pain,
bottom of
cutout to top of
cabinet door
30" rein,
_--- cabinet
28=1/2"
-._--- cutout ---_
width
Doubb oven
1" top of cutout
to bottora of
upper cabinet
door
14=3/4"
bottom
of cutout
to eoor
1" top of cutout
to bottom of
upper cabinet
door
cabinet/-_
23=1/4"rain.
cutout depth
23"recessed
oven depth
recessed
oven
oven
_/'front
t
32"
bottom of
cutout to
floor
Cabinet side view
Cabinet filler kits are available from your dealer.
Use a matching color kit if oven is smaller than your
Single oven filler height is 3-5/18"
Black -- 4378941
White -- 4378942
Almond- 4378943
Doubb oven filler height is 6-5/16"
Black -- 4378947
White -- 4378948
Almond- 4378949
Your safety ned the safety of others are
very important,
We have provided many important safety
messagesin this manualand on your appliance.
Atways read and obey aIIsafety messages.
This is the safety alert symbol.
Thissymboi alertsyou to potential hazards
that can kiii or hurt you and others.
Ati safety'messageswiii foiiow the safetyalert
symbol andeither the word "DANGER"or
"WARNING".Thesewords mean:
Yea can be killed or seri0asty injured if you
don't f0H0w instructions.
AIi safety messageswiii teii you what the potential
hazardis, tell you howto reducethe chance of
injury, andteti you what can happenif the
instructions are not followed.
important: Observe all governing codes
and ordinances.
Proper installation is your responsibility.
Have a qualified technician install this oven.
Oven bcation should be away from strong draft
areas, such as windows, doors and strong
heating vents.
Cabinet opening dimensions that are shown
must be used. Given dimensions provide
minimum clearance.
Recessed installation area must provide
complete enclosure around the recessed portion
of the oven.
Ebctrical ground is required. See "Electrical
requirements."
Ebctrical supply junction box should be located
3 inches maximum below the support surface
when oven is installed in a wall cabinet. Drill a
14nch minimum diameter hob in the right rear
or [eft rear corner of the support surface to pass
the appliance came through to the junction box.
For undercounter installation, it is recommended
that the junction box be located in the adjacent
right or left cabinet, if installing the junction box
on rear wall behind oven, junction box must be
recessed and located in the upper or lower right
or left corner of cabinet.
Oven support surface MUST be solid, level and
flush with bottom of cabinet cutout.
It is the customer's responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is
adequate and in conformance with National
Electrical Code, ANaltNFPA 70 _ latest edition*,
and nit local codes and ordinances.
Copies of the standards _isted may be obtained from:
* National Fire Protection Association
Batteryraarah Park
Quincy, Massachusetts 02289
Tool needed:
Phillips
screwdriver
Partssupplied:
(_ 4 screws (double oven)