Installation guide

Explosion Hazard
Keep flammable materials and
vapors, such as gasoline, away from
dryer,
Place dryer at [east 18 inches above
the floorfora garage installation.
Faiture to do so can result in death,
explosion, or fire,
43-1/8"
2%1/4"* (models with flusl-
strain re[ief
mounted door handle)
30-1/4"* (models wRh
\
extended door handle) _27"
*Most models will require at least 5" clearance behind the dryer for the dryer vent,
Forproperdryingperformance:
The location must provide:
_/Protection from weather and water: Do not
store or use dryer where it wii[ be exposed to
water and weather.
_'Room temperature above 45°F: Ifroom
temperature is below 45°F, automatic cycles may
not shut off.
_'Leve[ floor: Maximum slope under entire dryer
should not be more than 1 inch. (If slope is greater
than 1 inch, install Extended Dryer Feet Kit, Part
No. 279810.) Clothes may not tumble properly and
automatic sensor cycles may not operate correctly if
dryer is not level.
_'Sturdy floor to support dryer weight of
120 pounds.
The dryer
door
extends
14" from
the front
of the
dryer
when fully
opened.
Exhaustdimensieas
back exhaast
0 r> 0
J
/r-,_
14-1/8" [_ T
4-1/4"
bettem exhaast
/
k
7-1/4"
it is yearresponsibiJityto:
_/Observe all governing codes and ordinances.
_'Check code requirements: Some codes [imit or
do not permit instailation of clothes dryers in
garages, closets, mobile homes or sieeping
quarters. Contact your local building inspector.
_'Compiy with the installation specifications and
dimensions.
_'Consider spacing requirements for companion
appliances.
_'Make sure you have everything necessary for proper
installation.
_'Propedy install dryer.
_'Contact a qualified installer to insure that the
electrical installation meets all national and local
codes and ordinances.
Recessedarea/closet installation
WARNING -- To reduce the risk of fire this appliance
MUST BE EXHAUSTED OUTDOORS
Recessedarea iastaiiatiea
installation clearances
Use recommended clearance for easier installation.
Recommended/Minimum
Back Sides Top Front
Recessed 5"/0" 1'70" 18"/15" --
Closet 5"/0" 1"/0" 18"/15" 1"/1"
* A clothes dryer produces combustible lint and
must be exhausted outdoors.
If codes permit, dryer may be installed in a
recessed area or closet using dimensions shown.
Dimensions are in inches and are the minimum
allowable.
Additional spacing should be considered for ease
of installation and servicing. Companion
appliance spacing should also be considered.
front view
Cleset!eeafiaed area iastaiiatiea
mf a closet door is instalied: The minimum
unobstructed air openings are required. Louvered
doors with equivalent air openings are acceptable.
side view
* Wall, door and floor molding may require
additional spacing.
** Minirnurn top a bottom air openings for closet door.
*** External exhaust elbow requires additional space.
If codes permit and a separate ground wire is
used, it is recommended that a qualified electrician
determine that the ground path is adequate.
Important: Observe a[[ governing codes and
ordinances.
A four-wire or three-wire, singie phase, 120/240-
volt, 60-Hz, AC-only, electrical supply (or four-wire
or three-wire, 120/208-volt if specified on
model/serial rating plate) is required on a separate
30-ampere circuit, fused on both sides of the line. A
time-delay fuse or circuit breaker is recommended.
Recemmendedgreundmethod
It is the personal responsibility and obligation of the
customer to contact a qualified electrician to assure
that the electrical installation is adequate and is in
conformance with the National Electrical Code,
ANSI/NFPA 70 -- latest edition .... and all local
codes and ordinances.
Copies of the standards listed above may be obtained
from:
****National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
Panel A