Installation guide

Fire Hazard
Use a heavy metal vent.
Do not use a piastB vent,
Do not use a metal foi[ vent.
Faiture to do so can result in death or fire.
Important: Observe alt governing ¢odes and
ordinances.
mtis recommended that you exhaust your dryer to
the outside for best performance. Moisture and lint
indoors may cause:
* Lint to gather around the dryer where it can be fuel
for a fire.
Moisture damage to woodwork, furniture, paint,
wallpaper, carpet, etc.
Housecleaning problems and heakh problems.
Dura Safe TM venting products are recommended
and are available from your deaJero
Fourdnch diameter vent must be used.
Use a heavy metal vent. Do Not use plastic or metal
foil vent.
o Do Not use non°meta[ flexible vent, or exhaust
hoods with magnetic Iatches.
Do Not exhaust dryer into a chimney, wail, ceiling,
furnace, coM air vent, duct, concealed space, attic
or craw[ space, or any other vent used for venting.
Do Not install flexible vent in enclosed walls,
ceilings or floors.
Rigid metal vent is recommended to prevent
crushing and kinking.
Flexible metal vent must be fully extended and
supported when the dryer is in its final position.
Remove excess flexible vent to avoid sagging and
kinking that may result in reduced air flow.
An exhaust hood should cap
the exhaust vent to prevent
rodents and insects from entering
the home.
Exhaust outlet hood must be at
least 12 inches from the ground or
any object that may be in the path
of the exhaust (such as flowers,
rocks or bushes, etc.).
If using an existing exhaust
system, clean lint from entire
length of system and make sure exhaust hood is
not plugged with lint. Replace any plastic or metal
foil vent with rigid metal or flexible metal vent.
Use damps to seal all joints. Do Not use duct tape,
screws or other fastening devices that extend into the
interior of the vent to secure vent.
M@iie heme [nstaiJatienrequirements
If codes permit, this appliance [s suitable for mobile
home installations. The instai[at[on of the dryer must
conform to Manufactured Home Construction and
Safety Standard, Title 24 CFR, Part 3280 (formerly the
Federal Standard for Mobile Homes Construction and
Safety, Title 24, HUD Part 280) or latest edition.
The dryer must be exhausted outside.
,,oor kL
enclosed area
outside
waJ[
The exhaust vent must be securely fastened to a
non-combustible protion of the mobile home
structure and must not terminate beneath the
mobile home,
Planthe exhaustventinstaliatien
Beute the vent
The exhaust outlet is located at the center of the
rear of the dryer.
The exhaust vent can be routed up, down, [eft,
right or straight out the back of the dryer, See
"Recessed area/closet installation" section, Panel A,
for general space requirements.
better
exhaust air flow
Preferred--
rear of the dryer.
straight back
offset_
This dwer may be converted to exhaust
out the right or left side or through the bottom.
To convert the dryel, the folIowing kits are available
from your dealer:
Exhaust Kit No. 279818 (white)
Exhaust Kit No. 279819 (almond)
Exhaust Kit No. 279925 (biscuit)
Exhaust Kit No. 279969 (silver)
Typical installations
for [eft or right side
exhausting.
Typical installations
for bottom
exhausting.
Select the route that will provide the straightest
and most direct path outdoors. Plan the installation
to use the fewest number of elbows and turns.
When using eBbows or making turns, allow as much
room as possible, Bend vent gradually to avoid
kinking,
Determine exhaust vent Jength
The maximum length of the exhaust system depends
upon:
the type of vent (rigid or flexible metal).
the number of elbows used.
side or bottom exhaust. Side or bottom exhaust
adds a 90 ° turn inside the dryer, To determine
maximum exhaust length, add one 90 ° turn to the
chart.
1. See the exhaust vent length chart that matches
your type hood for the maximum vent lengths you
can use,
2_
3.
Do not use vent runs longer than specified in
exhaust vent length charts.
Exhaust systems Ionger than specified will:
-- accumulate lint creating a potential fire
hazard.
-- shorten the Iife of the dryer.
-- reduce performance, resulting in Ionger
drying times and increased energy usage.
Determine the number of elbows you will need.
In the column listing the type of metal vent you are
using (rigid or flexible), find the maximum length
of metal vent on the same line as the number of
elbows.
Determine the number of 4" clamps you will need.
Number of
90 ° elbows
0
1
2
g
4
,Maximum length of
4 diameter metal vent
Rigid Flexible
(fully extended)
64 ft. 36 ft.
54 ft. 31 ft.
44 ft. 27 ft.
35 ft. 25 ft.
27 ft. 23 ft.
Acceptable --
__2-1/2"
,Maximum length of
4 diameter metal vent
Rigid Flexible
Number of
90 ° elbows (fully extended)
0 58 ft. 28 ft.
1 48 ft. 23 ft.
2 38 ft. 19 ft.
3 29 ft. 17 ft,
4 21 ft. 15 ft.
The maximum length using a 2" x 6" rectangMar
vent with 2 elbows and a 2-1/2 exhaust hood is
8 ft.
For exhaust systems not covered by exhaust vent
length charts (such as multiple unit hookups,
plenums, and poweroassist fans), see Service
Manual, Part No. 60319Z (To purchase the Service
Manual, see your Use and Care Guide for a toll-free
telephone number.)