Electrical connection must be made before connecting the appliance to the electricity
supply. The appliance must be installed by a qualified electrician who is fully aware of
current safety and installation regulations. Specifically, installation must be carried out in
compliance with the regulations of the local electricity supply company. Make sure that the
voltage indicated on the rating plate corresponds to the voltage in your home. Regulations
require that the appliance be earthed: use conductors (including the earth conductor) of the
appropriate size only. The manufacturer declines all liability for injury to persons or animals
and for damage to property resulting from failure to observe the above regulations. For the
electrical connection use a H05RR-F type cable as indicated in the table below:
POWER SUPPLY VOLTAGE
The appliance must be connected to the electricity supply by means of an all-pole
disconnect switch with minimum contact gap of 3 mm.
ATTENTION:the power supply cable must be long enough to allow the hob to be removed
from the worktop and must be positioned so as to avoid damage or overheating caused by
contact with the base.
CONNECTING TO THE TERMINAL BOARD
N.B.:the yellow/green earth wire must be connected to the terminal with the symbol
and must be longer than the other wires.
Remove approx. 70 mm of the cable sheath from the power supply cable (B).
Strip approx. 10 mm of sheath from the wires. Then insert the power supply cable
into the cable clamp and connect the wires to the terminal block as indicated in the
connection diagram placed close to the terminal block itself.
Secure the power supply cable (B) by means of the cable clamp.
Close the terminal board with the cover (A) securing it with the screw provided.
After the electrical connection, fit the hob from the top and hook it to the support
springs, following the diagram.
ELECTRICAL CONNECTIONS
Conductors Amount x size
220-240V ~ +
3 X 2.5 mm
2
220-240V 3~ +
4 X 1.5 mm
2
380-415V 3N ~ +
5 X 1.5 mm
2
380-415V 2N ~ +
4 X 1.5 mm
2
A B