Owner's Manual
Table Of Contents
- DRYER SAFETY
- Dryer Safety
- DRYER MAINTENANCE AND CARE
- Cleaning the Dryer Location
- Cleaning the Dryer Interior
- Removing Accumulated Lint
- Cleaning the Lint Screen
- Check Your Vent System for Good Airflow
- Maintain Good Airflow
- Nonuse, Storage, and Moving Care
- INSTALLATION INSTRUCTIONS
- REQUIREMENTS
- Tools and Parts
- Location Requirements
- Electrical Requirements
- Electrical Requirements – U.S.A.
- Electric Requirements – Canada
- INSTALLATION
- Install Leveling Legs
- Electrical Installation – U.S.A.
- Home Venting Requirements
- Plan Vent System
- Install Vent System
- Connect Vent (Vented Models Only)
- Level Dryer
- Complete Installation Checklist
- SECURITE DE LA SECHEUSE
- Sécurité de la sécheuse
- ENTRETIEN ET REPARATION DE LA SECHEUSE
- Nettoyage de l’emplacement de la sécheuse
- Nettoyage de l’intérieur de la sécheuse
- Retrait de la charpie accumulée
- Nettoyage du filtre à charpie
- Vérification d’une circulation d’air adéquate pour le système d’évacuation
- Pour maintenir une bonne circulation d’air
- Précautions à prendre lorsque l’appareil n’est pas utilisé, est entreposé ou déménagé
- INSTRUCTIONS D'INSTALLATION
- SPECIFICATIONS
- Outils et pièces
- Exigences d’emplacement
- Spécifications électriques
- Spécifications électriques – É.-U.
- Spécifications électriques – Canada
- INSTALLATION
- Installation des pieds de nivellement
- Installation électrique – É.-U.
- Exigences concernant l’évacuation pour une maison
- Planification des circuits de conduits
- Installation du conduit d’évacuation
- Raccordement du conduit d’évacuation (sur les modèles avec conduit seulement)
- Réglage de l’aplomb de la sécheuse
- Liste de vérification pour installation terminée
- Blank Page
- Blank Page
- Blank Page
- Blank Page
11
4-Wire Power Supply Connection
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3-wire
connections.
A. 4-wire receptacle
(NEMA type 14-30 R)
B. 4-prong plug
C. Ground prong
D. Neutral prong
E. Spade terminals with
upturned ends
F. 3/4" (19 mm) UL-listed
strain relief
G. Ring terminals
3. Prepare ground wire appliance installation
Remove center terminal block screw (B). Remove neutral
bond wire (E) from green external ground conductor screw
(A).
4. Connect neutral bond wire and neutral wire
Connect neutral bond wire (E) and neutral wire (white or
center) (C) of power supply cord under center terminal
block screw (B). Tighten screw.
5. Connect ground wire
Connect ground wire (F) (green or bare) of power supply cord
under green external ground conductor screw (A). Tighten
screw.
6. Connect remaining wires
Connect remaining wires under outer terminal block screws.
Tighten screws. Insert tab of terminal block cover into slot of
dryer rear panel. Secure cover with hold-down screw. Now,
go to “Venting Requirements.”
3-Wire Power Supply Connection
IMPORTANT: Use where local codes permit connecting cabinet-
ground conductor to neutral wire.
A. 3-wire receptacle
(NEMA type 10-30R)
B. 3-wire plug
C. Neutral prong
D. Spade terminals with
upturned ends
E. 3/4" (19 mm) UL-listed
strain relief
F. Ring terminals
G. Neutral (white or center
wire)
3. Remove center screw
Remove center terminal block screw (B).
4. Connect neutral wire
Connect neutral wire (white or center) (C) of power supply
cord under center terminal block screw (B). Tighten screw.