Specification

IMPORTANT
After finishing the range conversion, the installer must tape a plate indicating the new
conditions of the gas supply for the appliance.
INSTALLATION USING NATURAL GAS OR LP GAS FROM A PIPE LINE
· This stove is prepared to work with LP gas.
· The technical specifications for this range are on the identification label on the back of this product.
· In order to connect this range to Natural gas or LP gas, it is necessary that the gas supply valve it’s located
behind the range and use the correct installation materials, approved by the local regulations.
· The operations to convert your range to Natural Gas or LP gas from a pipe line must be performed by a
qualified installer from the Whirlpool Service Center
RECOMMENDATIONS
· After the gas supply has been installed, check that there is no leakage by applying soapy water to all
connections and joints of the hose and pipes. If you see bubbles coming out, the installation was not carried out
correctly and must be installed again.
· The hose or pide should not be bent, tense or too close to heat sources.
· If the installation it’s not new, clean the pipes to prevent the range nozzles from clogging.
· To facilitate the movement of the appliance, the installer should make a coil with the flexible copper piping and
install a shutoff valve in the supply line. The valve should be installed separate from the range and accessible
for whoever is operating the range.
This valve must be outside of the range and accessible for the people using the appliance.
2. Use a screwdriver to tighten the metallic clamp around the
hose (Fig. 2).
3. Place the other bracket on the other end of the gas hose
and connect the other end of the hose to valve in the gas
cylinder. Tighten the metal bracket with the screwdriver
(Fig. 3).
4. Make sure the gas valve is closed before making the
connection to the gas tank (Fig. 4)
IMPORTANT:
5. After the gas supply has been installed, check that there is
no leakage by applying soapy water to all connections and
joints of the hose and pipes. If you see bubbles coming out,
the installation was not carried out correctly and must be
installed again (fig. 5).
The hose should not be bent, tense or too close to heat
sources.
- It is not recommended to place the gas cylinder next to the range. In case of problems, consult your Whirlpool
Service Center.
IMPORTANT: The installation must be performed by qualified personnel.
2
3
4
5
33