COLLECTION OWNER'S MANUAL pedicure spas by
Owner’s Manual Standard Whirlpool Jet SANIJET® Pipeless (Optional) PETRA PETRA PETRA PETRA PETRA PETRA PETRA PETRA PETRA PETRA 700 500 450 350R** or V*** 300 700-S* 500-S 450-S 350R** or V***-S 300-S S*=SANIJET® Pipeless R**=Roller Massage V***=Vibration Massage Table of Contents Introduction & Safety Standards 3 Important Considerations 4 Identifying Parts & Description (For Petra 700 & 500) 5 Massage System (For Petra 450, 350R, 350V & 300) 6 Chair Assembly (For Petra 700&500) 7 Chair Ass
Introduction Thank you for purchasing the PETRA Whirlpool Pedicure Spa. This finest Whirlpool Pedicure Spa has been developed by J&A USA, Inc. to operate dependably for many years when used properly. Please take time to read this entire manual thoroughly before installation and use. PLEASE READ AND FOLLOW INSTRUCTIONS CAREFULLY! Important Precautions J&A USA requires that you contact your local, qualified electrician and plumber to install your PETRA Whirlpool Pedicure Spa.
Important Considerations Please read the following instructions thoroughly Inspection Please take time to inspect each pedicure spa shipment thoroughly for damages immediately upon delivery. If damages are found, it is very important to notify the freight driver and indicate extent of the damages on the bill of lading. If you fail to do so, J&A USA will not be responsible for the damages and may not be able to make appropriate claims to the freight carrier.
PETRA 700 & 500 IDENTIFYING PARTS 20 19 1 A STOP 15 FORWARD BACKWARD B KNEAD TAP 2 UP DOWN AUTO CONTINUE/REPEAT 3 THIGHMASSAGE UP MASSAGEWHEELS 4 J&A DOWN 5 16 6 7 8 9 17 10 11 13 12 18 14 Standard Whirlpool Jet SANIJET-Pipeless PARTS 1 - PILLOW COVER 11 - SANIJET PUMP IMPELLER 2 - BACK REST 12 - OVERFLOW WASTE KNOB 3 - ARM REST 13 - POP-UP DRAIN STOPPER 4 - MATCHING ARM TRAY (OPTIONAL) 14 - LIGHT COVER 5 - SEAT CUSHION 15 - BACK PANEL 6 - SHOWER SPRAYER 16 - ARM
PETRA 450, 350R, 350V & 300 MASSAGE SYSTEM PETRA 300 PETRA 450 Pacific spa J &A J&A USA Inc. VIBRATION VIBRATION TRANSFORMER MODEL:GRA 1215 INPUT: AC 120V, 60Hz OUTPUT: DC 12V, 1.5A TRANSFORMER MODEL: GRA 1215 INPUT: AC 120V, 60Hz OUTPUT: DC 12V, 1.5A PETRA 350 V PETRA 350 R TIMER ROLLER HEC BACK VIB WAIST SEAT SPD SEL Pacific Spa AUTO ByJ&AUSA ROLLER MASSAGE & VIBRATION VIBRATION TRANSFORMER MODEL: AD-57241200 INPUT: 120V, AC 60Hz OUTPUT: 24V, DC 1.
PETRA 700 & 500 SERIES CHAIR ASSEMBLY PETRA 700 IMPORTANT ASSEMBLY INSTALLATION STOP KNEAD PRIOR TO USE TAP AUTO A 8 FORWARD CONTINUE/REPEAT BACKWARD B THIGHMASSAGE UP UP DOWN MASSAGEWHEELS J&A DOWN BEFORE ASSEMBLY HOT AFTER ASSEMBLY 8 COLD 1 2 4 3 5 1) LIGHT BOX POWER CORD 2) SLIDER / RECLINER POWER CORD 3) SANIJET CONTROL BOX POWER CORD 4) CHAIR MASSAGE POWER CORD 5) HITCH PIN CLIP 6) RECLINING PISTON 7) CLEVIS PIN 8) SUPPORT ARM BRACKET 7 6 CHAIR ASSEMBLY FOR PETRA 700 & 500
PETRA Chair Assembly for 450, 350R, 350V, 300 Rear View PETRA 300 PETRA 450 PETRA 350R & 350V CHANNEL FRAME HOT HOT HOT COLD COLD COLD 1) REMOVE THE LOCK NUT FROM THE BOLTS 2) ALIGN FOUR BOLTS WITH FOUR HOLES ON THE CHANNEL FRAME 3) TIGHTEN EACH LOCK NUTS TO SECURE THE CHAIR TO THE BASE Bolt Channel Frame Washer Lock Nut 8
PETRA COLLECTION SPECIFICATIONS PETRA 700 & 500 55 25 18 19 18 2.5 43 24 8 3/4 6 3/4 27 28 57 41 WALL HOT & COLD 0.5 inches Fittings included PETRA 450, 350R, 350V & 300 48 24 17 18 17 1.5 43 24 8 3/4 6 3/4 27 28 57 44 HOT & COLD 0.
Plumbing Connections All plumbing connections should be made by a qualified, licensed plumber in accordance with local plumbing and building codes. Hot and Cold Water Supply Lines Connect 1/2” ID supply tubes to a fresh water source. Shut-off valves should be utilized. Electrical Connections The Foot spa must be plugged into a GFCI protected outlet, installed by a licensed electrician. Testing the Foot spa Clean the tub and fill with water to the wave-mark (water level) on the wall of the tub.
FOR SANIJET® -PIPELESS SYSTEM USERS ONLY Maintenance Keep the screen of the jet inlet free of debris, any blockage of the screen reduces the whirlpool action and may cause damage to the jet motor. Cleaning Pipeless Jet System Remove the jet assembly from its casing: Rotate the jet assembly counterclockwise and pull outward. Remove the impeller cap: rotate the impeller cap clockwise (OFF) and life outward. Remove impeller. Clean the components.
Caution To reduce the potential risk of fire, electrical shock, or injury to persons: 1) All electrical wiring (both installation & repair) must be done by a licensed electrician and in accordance with local and state ordinances. 2) No modifications, additions or deletions should be made to the pump, without factory approval. 3) Before stating motor, fill up the tub with water to level recommended by whirlpool manufacturer. Never run pump dry! 4) Do not relocate pump without prior approval from factory.
FOR STANDARD WHIRLPOOL SYSTEM USERS ONLY Maintenance Keep the screen of the suction inlet free of debris, any blockage of the screen reduces the whirlpool action and may cause damage to the whirlpool pump motor. Cleaning/ Flushing the inner whirlpool system Fill up with warm water up to proper level. Apply 3 tsp of low foaming dish washing detergent, 1 tsp of the regular bleach into the tub. Start the whirlpool for 5 min and let it still for 5 min and run again for two minutes.
CAUTION To reduce the potential risk of fire, electrical shock, or injury to persons: 1) All electrical wiring (both installation & repair) must be done by a licensed electrician and in accordance with local and state ordinances. 2) No modifications, additions or deletions should be made to the pump, without factory approval. 3) Before starting motor, fill tub with water to level recommended by whirlpool manufacturer.
Discharge Pump Installation (Optional) POWER CORD ON/OFF DISCHARGE SWITCH MUST BE PLACED HIGHER THAN WATER LEVEL CONVERTER BOX AIR TUBING WATER LEVEL Tub Outlet Check Valve must be installed to prevent back flow B A AIR VENT HOSE ATTACHMENT PIPE Main Drain Pipe L-TRAP DISCHARGE PUMP To prevent the possible air lock, B has to higher than A - Outlet from drain pump must be placed on top of the main drain pipe - Do not use flexible pipe for drain FAQ 1) Pump hums but does not drain the water ou
Lubrication 1) Turn off the main power 1) Open the screws (phillip+) or Open the zippers from the front of the chair 2) Apply lubrication onto circled area Caution Do not apply lubrication on dc-belt BACK VIEW FRONT VIEW REMOVE SCREWS (PHILLIP) TO OPEN THE PANEL DC-PULLEY DC-BELT GEAR PULLEY UPPER SENSOR IMPORTANT!!! DC-MOTOR GEAR BOX LUBRICATE ON CIRCLED AREA MACHINERY OIL RECOMMENDED OIL RESERVOIR LOWER SENSOR MAIN SHAFT MAIN ON/OPF POWER SWITCH AC MOTOR TRANSFORMER PCB BOARD FUSE MAIN SHAFT
J&A USA, INC. LIMITED WARRANTY STATEMENT J&A Product: EPISODE, PETRA, TOEPIA, CLEO, PACIFIC SPA J&A Accessories: Epi-Stool, Tri-Stool, __________ Duration of limited warranty: 1 year from date of purchase Coverage on limited warranty: Parts & Labor EXTENT OF LIMITED WARRANTY J&A USA warrants that the J&A product and/or accessories specified above will be free from defects in materials and workmanship for the duration specified above.
MULTI-COLOR LED SPA LIGHT (Instruction for LED Bulb replacement) WARNING: Rick of electric shock!!!, Drain spa and disconnect power before attempting to open lens. Multicolor LED spa lights allows the replacement of the lamp from the front. It comes complete with a plastic insert tool for tightening, or un-tightening. NOTE: To change a bulb after installation, follow the instruction engraved on the lamp replacement too.
QMTX.E242637 Plumbing Accessories See General Information for Plumbing Accessories J & A USA INC 200 RODEO DR EDGEWOOD, NY 11717 USA E242637 Whirlpool pedicure spas, Models PS300, PS650LX, Episode, Episode-S Type, Toepia EM, Cleo , Petra. Last Updated on 2004-10-19 This page and all contents are Copyright © 2005 by Underwriters Laboratories Inc.