Thank you very much for purchasing this Air Conditioner. Please read this use and installation instructions carefully before installing and using this appliance and keep this manual for future reference.
Contents safety instructions 4 Product description 12 Indoor unit 12 Outdoor unit 12 Display introduction 13 Emergency button 15 Safety precautions 16 Maintenance 17 Protection 18 Troubleshooting 19 Installation instructions 20 Indoor unit installation 21 Outdoor unit installation 25 Remote control of P1-03 31 Remote control of P1-04 40 Remote control of J1-3A 49
SAFETY INSTRUCTIONS IMPORTANT TO BE READ AND OBSERVED • Download the complete instruction manual on docs.whirlpool.eu or call the phone number shown on the warranty booklet. • Before using the appliance, read these safety instructions. Keep them nearby for future reference. • These instructions and the appliance itself provide important safety warnings, to be observed at all times.
SAFETY INSTRUCTIONS • When moving or relocating the air conditioner, consult experienced service technicians for disconnection and reinstallation of the unit. • The appliance shall not be installed in the laundry. ELECTRICAL WARNINGS • The power supply must be of rated voltage with special circuitry for the appliance. The diameter of the power cord must comply with requirements.
SAFETY INSTRUCTIONS DISPOSAL OF HOUSEHOLD APPLIANCES This appliance is manufactured with recyclable or reusable materials. Dispose of it in accordance with local waste disposal regulations. For further information on the treatment, recovery and recycling of household electrical appliances, contact your local authority, the collection service for household waste or the store where you purchased the appliance.
SAFETY INSTRUCTIONS transport regulations. 2. Marking of equipment using signs shall be compliant with local regulations. 3. Disposal of equipment using flammable refrigerants shall be compliant with national regulations. 4. The storage of equipment / appliances should be in accordance with the manufacturer’s instructions. 5.
SAFETY INSTRUCTIONS released refrigerant and preferably expel it externally into the atmosphere. 6-8 Checks to the refrigeration equipment Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance.
SAFETY INSTRUCTIONS The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment. Intrinsically safe components do not have to be isolated prior to working on them. 8. Repair to intrinsically safe components Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use.
SAFETY INSTRUCTIONS -- Purge again with inert gas; -- Open the circuit by cutting or brazing. The refrigerant charge shall be recovered into the correct recovery cylinders.The system shall be “flushed” with OFN to render the unit safe. This process may need to be repeated several times. Compressed air or oxygen shall not be used for this task. Flushing shall be achieved by breaking to fill until the working pressure is achieved, then venting to atmosphere, and finally pulling down to a vacuum.
SAFETY INSTRUCTIONS h. Do not overfill cylinders. (No more than 80 % volume liquid charge). i. Do not exceed the maximum working pressure of the cylinder, even temporarily. j. When the cylinders have been filled correctly and the process completed, make sure that the cylinders and the equipment are removed from site promptly and all isolation valves on the equipment are closed off. k. Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked. 15.
Product description Indoor unit Front Panel Air Intake Display Panel Emergency Panel Air Outlet Vertical Adjustment Louver Horizontal Adjustment Louver Air Filter Remote Controller Air Intake Outdoor unit Pipes and Power Connection Cord Drain Hose Note: Condensate water drainsat COOLING or DRY operation. Air Outlet The figures in this manual are based on the external view of a standard model. Consequently, the shape may differ from that of the air conditioner you have selected.
Display introduction Temperature indicator 1 Display set temperature. It shows FC after 200 hours of usage as reminder to clean the filter. After filter cleaning press the filter reset button located on the indoor unit behind the front panel in order to reset the display.(optional) It displays set humidity in humidity mode.(optional) Running indicator 2 It lights up when the AC is running. It flashes during defrosting. Timer indicator It lights up during set time.
Display introduction TJ series 6 3 3 9 1 2 4 2 TJ/LB/CC series (hidden display) 7 2 7 5 8 1 2 3 6 4 1 8 1 9 9 8 1 9 3 6 The symbols may be different from these models, but the functions are similar.
Emergency button Emergency button 10 ON/OFF To let the AC run or stop by pressing the button. Filter reset button 11 To reset filter clean indicator by pressing the button. 10 Emergency button 10 ON/OFF To let the AC run or stop by pressing the button. 10 FOR THE MULTI SYSTEM ON/OFF you can stop the unit immediately by pressing the button. Force COOLING : you can force the unit to run in cooling mode and high fan speed by pressing the button for 5 seconds.
Safety precautions Symbols in this Use and Care Manual are interpreted as shown below. Be sure not to do. Grounding is essential. Pay attention to such a situation. Warning: Incorrect handling could cause a serious hazard, such as death, serious injury, etc. Use correct power supply in accordance with the rating plate requirement. Otherwise, serious faults or hazard may occur or a It is harmful to your health if the cool fire maybe break out. air reaches you for a long time.
Maintenance Front panel maintenance Cut off the power supply a Grasp position "a" and pull outward to remove the front panel. Turn off the appliance first before disconnecting from power supply. a Never use volatile substance such as gasoline or polishing powder to clean the appliance. Wipe with a soft and dry cloth. Use soft moisture cloth to clean if the front panel is very dirty; Use a dry and soft cloth to clean it. Never sprinkle water onto the indoor unit Reinstall and shut the front panel.
Protection Operating condition Operating temperature Cooling operation(DB/WB) Heating operation(DB/WB) Drying operation(DB/WB) max 32℃/23℃ 27℃/18℃ 32℃/23℃ min 21℃/15℃ 20℃/15℃ 18℃ max 43℃/26℃ 24℃/18℃ 43℃/26℃ min -15℃/-16℃ -15℃/-16℃ 21℃ Temperature Indoor temperature Outdoor temperature NOTE: *Optimum performance will be achieved within these operating temperature. If air conditioner is used outside of the above conditions, the protective device maybe trip and stop the appliance.
Troubleshooting The following cases may not always be a malfunction, please check it before asking for service. Trouble Analysis If the protector trip or fuse is blown. Please wait for 3 minutes and start again, protector device may be preventing unit to work. .If batteries in the remote controller exhausted. If the plug is not properly plugged.
Installation instructions Installation diagram Distance from ceiling Distance from wall should be over 50mm should be over 200 mm Distance from the wall should be over 50mm Distance from floor should be over 2500mm. Indoor unit A Above figure is only a simple presentation of the unit, it may not match the external appearance of the unit you purchased. Installation must be performed in accordance with the national wiring standards by authorized personnel only.
Installation instructions Indoor unit installation 1. Installing the Mounting Plate Decide an installing location for the mounting plate according to the indoor unit location and pipe direction. Keep the mounting. plate horizontally with a horizontal ruler or level. Drill holes of 32mm in depth on the wall for fixing the plate. Insert the plastic plugs to the hole, fix the mounting plate with tapping screws. Inspect if the mounting plate is well fixed. Then drill a hole for pipe.
Installation instructions Pipe Joints Thermal Insulation: Wrap the pipes joints with thermal insulation materials and then wrap with a vinyl tape. wrapped with vinyl type Thermal insulation Pipes Thermal Insulation: a. Place the drain hose under the pipes. b. Insulation material uses polythene foam over 6mm in thickness. Note: Drain hose is prepared by user. Large pipe Thermal insulation tube Power cord Drain pipe should point downward for easy drain flow.
Installation instructions The 18k indoor unit include the switch tie-in accessory only for 18K indoor. It may switch 9.52 gas connection tube into 12.7 connection tube. It is installed outdoor unit. If the flare joint nut assy has been loosened after it has been completely tightened, replace with a new flare joint nut assy. When removing the piping to relocate or repair the unit, replace with a new flare less joint nut assy. Gas valve Switch tie Connection tube Outdoor unit 4.
Installation instructions Caution: 1. Never fail to have an individual power circuit specifically for the air conditioner. As for the method of wiring, refer to the circuit diagram posted on the inside of the access door . 2.Confirm that the cable thickness is as specified in the power source specification.(See the cable specification table below). 3.Check the wires and make sure that they are all tightly fastened after cable connection. 4.
Installation instructions Installation diagram Air intake distance from the wall should be over 250mm Air intake distance from the wall should be over 250mm air sh outl ou et ld d be ista ov nce er 50 from 0m th m e over 250mm wa ll outdoor unit Above figure is only a simple presentation of the unit, it may not match the external appearance of the unit you purchased. Installation must be performed in accordance with the national wiring standards by authorized personnel only.
Installation instructions Select the installation locations Location for Installing Outdoor Unit Where it is convenient to install and well ventilated. Avoid installing it where flammable gas could leak. Keep the required distance apart from the wall. The distance between Indoor and outdoor unit should be 5 meters and can go up to maximum 15 meters with additional refrigerant charge. Keep the outdoor unit away from greasy dirt,vulcanization gas exit.
Installation instructions Connecting of the Cable Note: For some models, it is necessary to remove the cabinet to connect to the indoor unit terminal. Outdoor Unit 1) Remove the access door from the unit by loosening the screw. Connect the wires to the terminals on the control board individually as follows. Access door 2) Secure the power cord onto the control board with cable clamp. Terminal(inside) Outdoor unit 3) Reinstall the access door to the original position with the screw.
Installation instructions Wiring diagram Make sure that the color of the wires in the outdoor unit and terminal No. are the same as those of the indoor unit. 7K~24K Model Indoor unit Outdoor unit Terminal Terminal 0(L) Brown Gray 1(L) Power connecting cord e lu n ree w/G Ye llo lo Bl Ye l 0(L) 1(L) 2(N) k ac 4(SI) Bl 2(N) w / ac Gre k en B n Brow Gray Blu e 4(SI) BN BU L N YE/GN Power supply Warning: Before obtaining access to terminals,all supply circuits must be disconnected.
Installation instructions Outdoor unit installation 1. Install Drain Port and Drain Hose (for heat-pump model only) The condensate drains from the outdoor unit when the unit operates in heating mode. In order not to disturb your neighbor and protect the environment, install a drain port and a drain hose to direct the condensate water. Just install the drain port and rubber washer to the chassis of the outdoor unit, then connect a drain hose to the port as the right figure demonstrates.
Installation instructions How to Purge Air Tubes: (1) Unscrew and remove caps from 2 and 3-way valves. (2) Unscrew and remove cap from service valve. (3) Connect vacuum pump flexible hose to the service valve. (4) Start vacuum pump for 10-15 minutes until reaching a vacuum of 10 mm Hg absolutes. (5) With vacuum pump still running close the low pressure knob on vacuum pump manifold. Then stop the vacuum pump. (6) Open 2-way valve ,1/4 turn, then close it after 10 seconds.
REMOTE CONTROL FUNCTIONS AND INDICATORS (P1-03) P1-03 1. ON/OFF BUTTON Starts and/or Stops the appliance by pressing this button. 2. MODE BUTTON Used to select the operation mode. 3. FAN BUTTON Used to select fan speed in sequence auto, high, medium or low. 4-5. TEMPERATURE BUTTON Used to select the room temperature. Used to set time in timer mode and real time clock. 6. 6th SENSE BUTTON Sets or cancels 6th sense operation. 7.
STORAGE AND TIPS FOR USING THE REMOTE CONTROL How to insert the batteries 1. Insert a pin and gently press down on the battery cover and push in the direction of the arrow to remove, as shown. 2. Insert 2 AAA batteries (1.5V) into the compartment. Ensure that "+" and "-" polarity is correctly positioned. 3. Close the battery cover on the remote control. How to remove the batteries Remove the battery cover in the direction of the arrow.
OPERATING MODE DESCRIPTION Operation Modes: 1. Selecting mode Each time MODE button is pressed, the operation mode is changed in sequence: COOLING HEATING P1-03 FAN ONLY Heating mode is not available for cooling only air conditioners. COOLING mode: used to cool your room to feel cool and comfort in the hot season. DRY mode: used to remove moisture to feel comfort in a humid climate. FAN ONLY mode: used to ventilate your room, the air conditioner operates like a fan.
AIRFLOW DIRECTION CONTROL P1-03 5. Airflow direction control Horizontal airflow is automatically adjusted to a certain angle in accordance with the operation mode after turning on the unit. The direction of airflow can be also adjusted to your own requirement by pressing the "SWING" button of the remote control. Operation mode Direction of airflow COOLING, DRY horizontal *HEATING, FAN ONLY downward *Heating mode is only available for heat pump models.
MODE AND FUNCTION DESCRIPTIONS 6th SENSE MODE The sensor in the indoor unit, which measures temperature and humidity in the room, keeps the room temperature in the most comfortable level by controlling the temperature and the fan speed automatically.
SLEEP mode SLEEP mode can be set in COOLING, HEATING or DRY operation mode. This function gives you a more comfortable environment with low nois level for sleep. P1-03 The appliance will turn off automatically after operating for 8 hours. Fan speed is automatically set at low speed. For 9K/12K models only.
P1-03 JET mode • JET mode is used to start or stop fast cooling or Heating. Fast cooling operates at high fan speed, and set temperature automatically to 16°C. Fast heating operates at auto fan speed,changing set temperature automatically to 30 °C. • In JET mode, you can set airflow direction or timer. If you want to quit from JET mode, press any - JET , MODE, FAN, ON/OFF, SLEEP or TEMPERATURE SETTING button, the display will return to the original mode.
TIMER function It's convenient to set the timer on with TIMER button before you leave so that you will come back to the comfortable room temperature you set. Press the TIMER button to set a switch-on button when the appliance is off. Press the TIMER button to set a switch-off timer during operation. Increase Decrease How to set TIMER 1. Set desired operating mode, temperature setting and fan speed firstly, then press the TIMER button and "01h" flashed on LCD. 2.
P1-03 Around U function When you press this button, will display, remote control transmits the actual room temperature around it to the indoor unit, and the appliance will operate according to this temperature to let you feel more comfortable. Please keep the remote control in a location where it can transmit the signal to the indoor unit properly. Press once to set and press again to cancel. Room temperature will be displayed on remote controller screen once this function is set.
REMOTE CONTROL FUNCTIONS AND INDICATORS P1-04 1. ON/OFF BUTTON Starts and/or Stops the appliance by pressing this button. 2. MODE BUTTON Used to select the operation mode. 3. FAN BUTTON Used to select fan speed in sequence auto, high, medium or low. 4-5. TEMPERATURE BUTTON Used to select the room temperature. Used to set time in timer mode and real time clock. 6. 6th SENSE BUTTON Sets or cancels 6th sense operation. 7.
STORAGE AND TIPS FOR USING THE REMOTE CONTROL How to insert the batteries 1. Insert a pin and gently press down on the battery cover and push in the direction of the arrow to remove, as shown. 2. Insert 2 AAA batteries (1.5V) into the compartment. Ensure that "+" and "-" polarity is correctly positioned. 3. Close the battery cover on the remote control. How to remove the batteries Remove the battery cover in the direction of the arrow.
OPERATING MODE DESCRIPTION Operation Modes: 1. Selecting mode Each time MODE button is pressed, the operation mode is changed in sequence: COOLING FAN ONLY P1-04 HEATING Heating mode is not available for cooling only air conditioners. COOLING mode: used to cool your room to feel cool and comfort in the hot season. DRY mode: used to remove moisture to feel comfort in a humid climate. FAN ONLY mode: used to ventilate your room, the air conditioner operates like a fan.
AIRFLOW DIRECTION CONTROL 5. Airflow direction control Horizontal airflow is automatically adjusted to a certain angle in accordance with the operation mode after turning on the unit. The direction of airflow can be also adjusted to your own requirement by pressing the "SWING" button of the remote control. Operation mode Direction of airflow COOLING, DRY horizontal *HEATING, FAN ONLY downward P1-04 *Heating mode is only available for heat pump models.
MODE AND FUNCTION DESCRIPTIONS 6th SENSE MODE The sensor in the indoor unit, which measures temperature and humidity in the room, keeps the room temperature in the most comfortable level by controlling the temperature and the fan speed automatically.
SLEEP mode SLEEP mode can be set in COOLING, HEATING or DRY operation mode. This function gives you a more comfortable environment with low nois level for sleep. P1-04 The appliance will turn off automatically after operating for 8 hours. Fan speed is automatically set at low speed. For 9K/12K models only.
P1-04 JET mode • JET mode is used to start or stop fast cooling or Heating. Fast cooling operates at high fan speed, and set temperature automatically to 16°C. Fast heating operates at auto fan speed,changing set temperature automatically to 30 °C. • In JET mode, you can set airflow direction or timer. If you want to quit from JET mode, press any - JET , MODE, FAN, ON/OFF, SLEEP or TEMPERATURE SETTING button, the display will return to the original mode.
TIMER function It's convenient to set the timer on with TIMER button before you leave so that you will come back to the comfortable room temperature you set. Press the TIMER button to set a switch-on button when the appliance is off. Press the TIMER button to set a switch-off timer during operation. Increase Decrease How to set TIMER 1. Set desired operating mode, temperature setting and fan speed firstly, then press the TIMER button and "01h" flashed on LCD. 2.
P1-04 Around U function When you press this button, will display, remote control transmits the actual room temperature around it to the indoor unit, and the appliance will operate according to this temperature to let you feel more comfortable. Please keep the remote control in a location where it can transmit the signal to the indoor unit properly. Press once to set and press again to cancel. Room temperature will be displayed on remote controller screen once this function is set.