Instruction for Use

Cable Specifications
Attention:
Accessibility to the plug must be guaranteed even after the installation of the appliance to disconnect
it in case of need. If not possible, connect appliance to a double-pole switching device with contact
separation of at least 3 mm placed in an accessible position even after installation.
Indoor and outdoor
connecting wire specification
2
Cable 4-core 0.75mm , in conformity with
Design 245 IEC 57 or H07RN-F.
Indoor and outdoor
connecting wire specification
(for the 7K~12K mono split)
2
Cable 5-core 1.0mm , in conformity with
Design 245 IEC 57 or H07RN-F.
2
Cable 5-core 1.5mm , in conformity with
Design 245 IEC 57 or H07RN-F.
Indoor and outdoor
connecting wire specification
(for the 18K mono split)
24
2
Cable 5-core 2.5mm , in conformity with
Design 245 IEC 57 or H07RN-F.
Indoor and outdoor
connecting wire specification
(for the 24K mono split)
Installation instructions
Caution:
1. Never fail to have an individual power circuit specifically for the air conditioner. As for the method
of wiring, refer to the circuit diagram posted on the inside of the access door .
2.Confirm that the cable thickness is as specified in the power source specification.(See the cable
specification table below).
3.Check the wires and make sure that they are all tightly fastened after cable connection.
4. Be sure to install an earth leakage circuit breaker in wet or moist area.