Installation instructions
Select the installation locations
Location for Installing Outdoor Unit
Where it is convenient to install and well ventilated.
Avoid installing it where flammable gas could leak.
Keep the required distance apart from the wall.
The distance between Indoor and outdoor unit should be 5 meters and can go up to maximum 15 meters
with additional refrigerant charge.
A fixed base where it is not subject to increased operation noise.
Where there is not any blockage of the air outlet.
Keep the outdoor unit away from greasy dirt,vulcanization gas exit.
Avoid installing it by the roadside where there is a risk of muddy water.
Avoid installing under direct sunlight, in an aisle or sideway, or near heat sources and ventilation fans.
Keep away from flammable materials, thick oil fog, and wet or uneven places.
Outdoor unit
Indoor unit
Pipe length is
15 meters Max.
be less than 5m
Height should
Outdoor unit
Indoor unit
Pipe length is
15 meters Max.
be less than 5m
Height should
If the height or pipe length is out of the scope of the table, please consult the merchant.
Model
7K~18K
5
15
5
20
Max. Allowable Tubing
Length at Shipment (m)
Limit of Tubing
Length (m)
Limit of Elevation
Difference H (m)
Required amount of
additional refrigerant (g/m)
21K~24K
5
15
5
30